3-16
DSR-80/80P/60/60P
5
Main code 09
.
Main code 2X: Abnormality related to the mechanism control
1
Main code 20
2
Main code 21
3
Main code 22
Sub
code
028
209
221
224
821
824
Detected contents
Detected the abnormal threading motor current.
The full top or full end of a tape cannot be released
during threading even though short FF or short REW is
performed.
Failed to complete threading within the specified time
Failed to detect the threading FG during threading.
Failed to complete unthreading within the specified time
Failed to detect the threading FG during unthreading.
Operation after
detecting an
abnormality
AUTO OFF
Operable mode
EJECT
(Emergency EJECT)
Display period
Displayed until the
next cassette is
inserted.
Sub
code
018
111
911
Detected contents
Detected the abnormal current in the cassette up/down
motor.
Failed to complete the cassette down motion within the
specified time.
Failed to complete the cassette up motion within the
specified time.
Operation after
detecting an
abnormality
AUTO OFF
Operable mode
EJECT
(Emergency EJECT)
Display period
Displayed until the
next cassette is
inserted.
Sub
code
0C8
1C1
Detected contents
Detected the abnormal current in the reel position motor.
Failed to complete the reel position movement within the
specified time.
Operation after
detecting an
abnormality
AUTO OFF
Eject a cassette
tape.
Operable mode
EJECT
(Emergency EJECT)
_
Display period
Displayed until the
next cassette is
inserted.
Sub
code
0D8
Detected contents
Detected an abnormal current flowing through the
cleaning solenoid.
Operation after
detecting an
abnormality
AUTO OFF
Operable mode
EJECT
Display period
Displayed until the
next cassette is
inserted.
Summary of Contents for DVCAM DSR-60
Page 2: ......
Page 54: ......
Page 174: ......
Page 220: ......
Page 236: ......
Page 238: ...8 2 N DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 N DSR 60 80 ...
Page 242: ...8 2 P DSR 80 80P 60 60P SY 241B 241 CV101 CHARA SIZE 10 1 P DSR 60P 80P ...
Page 284: ......