10-17 (P)
DSR-80/80P/60/60P
Spec. (1) Turn RV601 counterclockwise fully.
(2) When RV601 is turned clockwise gradually, the phase
condition between CH-1 and CH-2 changes from NG to OK or
OK to NG.
(3) In case of the pattern of change is started from NG as shown
in the following illustration, set RV601 to mechanical center
of range of first OK.
NG
→
OK
→
NG
→
OK
↑
the mechanical center
of this range
(4) In case of the pattern of change is started from OK as shown
in the following illustration, set RV601 to mechanical center
of range of first OK.
OK
→
NG
→
OK
→
NG
↑
the mechanical center
of this range
*
*
*
*
*
If the range of first OK is extremely narrow, set to mechanical
center of range of second OK.