![SMC Networks 7724M/VSW - annexe 1 Manual Download Page 82](http://html1.mh-extra.com/html/smc-networks/7724m-vsw-annexe-1/7724m-vsw-annexe-1_manual_1299754082.webp)
Management Guide
CLI
TigerAccess™ EE
SMC7824M/VSW
81
To configure the power back-off length of each upstream band, use the following com-
mand.
Command Mode
Description
lre
PORTS
band-pbo-length u0
LENGTH
[
u1
LENGTH
]
lre
PORTS
band-pbo-length u0
LENGTH
u1
LENGTH
[
u2
LENGTH
]
lre
PORTS
band-pbo-length u0
LENGTH
u1
LENGTH
u2
LENGTH
[
u3
LENGTH
]
Bridge
Configures the power back-off length per upstream
band.
LENGTH: distance from 100m to 900m (1-10)
u1-u4: U1-U4 band configuration
The following table shows distance of 1 ~ 9 in the above command. Each variable means
as the below.
No
Distance (Unit : m)
No
Distance (Unit : m)
1
100
6
600
2
200
7
700
3
300
8
800
4
400
9
900
5
500
10
User Definition
Tab. 5.4
Value of PBO-Length
You should control supplied power of VDSL port according to distance of VDSL line.
The following is an example of configuring power consumption as 400m.
SWITCH(bridge)#
lre
1-5
pbo-length
4
SWITCH(bridge)#
show lre psd
1-7
-----------------------------------------------------------
Port Status Up Stream PBO Length PSD MASK
ADM/OPR PBO (10 Custom) Level
---------------------
| u0 | u1 | u2 | u3 |
-----------------------------------------------------------
1 Up/Down Enable | 4 | 4 | 4 | 4 | 1
2 Up/Down Enable | 4 | 4 | 4 | 4 | 1
3 Up/Down Enable | 4 | 4 | 4 | 4 | 1
4 Up/Down Enable | 4 | 4 | 4 | 4 | 1
5 Up/Down Enable | 4 | 4 | 4 | 4 | 1
6 Up/Down Enable | 2 | 2 | 2 | 2 | 1
7 Up/Down Enable | 2 | 2 | 2 | 2 | 1
SWITCH(bridge)#
!