![SMC Networks 7724M/VSW - annexe 1 Manual Download Page 148](http://html1.mh-extra.com/html/smc-networks/7724m-vsw-annexe-1/7724m-vsw-annexe-1_manual_1299754148.webp)
Management Guide
CLI
TigerAccess™ EE
SMC7824M/VSW
147
7.1.9.6 ERP
Alarm
Severity
To set severity of an alarm for ERP, use the following command.
Command Mode
Description
snmp alarm-severity erp-
domain-lotp
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for loss of test packet (LOTP)
in ERP domain.
snmp alarm-severity erp-
domain-multi-rm
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for multiple redundancy man-
agers (RM) created.
snmp alarm-severity erp-
domain-reach-fail
{
critical
|
ma-
jor
|
minor
|
warning
|
intermedi-
ate
}
Sets severity of an alarm for disconnection of ERP
domain.
snmp alarm-severity erp-
domain-ulotp
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Global
Sets severity of an alarm for loss of test packet (LOTP)
in ERP port.
To delete configured severity of an alarm for ERP, use the following command.
Command Mode
Description
no snmp alarm-severity erp-
domain-lotp
no snmp alarm-severity erp-
domain-multi-rm
no snmp alarm-severity erp-
domain-reach-fail
no snmp alarm-severity erp-
domain-ulotp
Global
Deletes configured severity of an alarm for ERP.
7.1.9.7
STP Guard Alarm Severity
To set severity of an alarm for STP guard, use the following command.
Command Mode
Description
snmp alarm-severity stp-bpdu-
guard
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets severity of an alarm for BPDU guard disabled.
snmp alarm-severity stp-root-
guard
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Global
Sets severity of an alarm for root guard disabled.