![SMC Networks 7724M/VSW - annexe 1 Manual Download Page 62](http://html1.mh-extra.com/html/smc-networks/7724m-vsw-annexe-1/7724m-vsw-annexe-1_manual_1299754062.webp)
Management Guide
CLI
TigerAccess™ EE
SMC7824M/VSW
61
4.5.1.4 Authentication
Port
After configuring 802.1x authentication mode, you should select the authentication port.
Command Mode
Description
dot1x nas-port
PORTS
Designates 802.1x authentication port.
no dot1x nas-port
PORTS
Global
Disables 802.1x authentication port.
4.5.1.5 Force
Authorization
The switch can permit the users requesting the access regardless of the authentication
from RADIUS server. For example, even though a client is authenticated from the server,
it is possible to configure not to be authenticated from the server.
To manage the approval for the designated port, use the following command.
Command Mode
Description
dot1x port-control
{
auto
|
force-
authorized
|
force-unauthorized
}
PORTS
Configures a state of the authentication port.
auto: authorization up to RADIUS server (default)
force-authorized: force authorization
force-unauthorized: force unauthorization
no dot1x port-control
PORTS
Global
Deletes a configured authentication port state.
4.5.1.6
Interval for Retransmitting Request/Identity Packet
In the switch, it is possible to specify how long the device waits for a client to send back a
response/identity packet after the device has sent a request/identity packet. If the client
does not send back a response/identity packet during this time, the device retransmits the
request/identity packet.
To configure the number of seconds that the switch waits for a response to a re-
quest/identity packet, use the following command.
Command Mode
Description
dot1x timeout tx-period
<1-
65535>
PORTS
Sets reattempt interval for requesting request/identity
packet.
1-65535: retransmit interval (default: 30)
no dot1x timeout tx-period
PORTS
Global
Disables the interval for requesting identity.
4.5.1.7
Number of Requests to RADIUS Server
After 802.1x authentication configured as explained above and the user tries to connect
with the port, the process of authentication is progressed among user’s PC and the
equipment as authenticator and RADIUS server. It is possible to configure how many
times the device which will be authenticator requests for authentication to RADIUS server.