7.4.1.4
Interval of Sample Inquiry
To configure the interval of sample inquiry in terms of second, use the following command.
Command Mode
Description
interval
<1-3600>
RMON
Defines the time interval for the history (in seconds),
enter the value. (default: 1800)
1 sec is the minimum time which can be selected. But the minimum sampling interval
currently is 30 sec, i.e., all intervals will be round up to a multiple of 30 seconds.
7.4.1.5
Activating RMON History
To activate RMON history, use the following command.
Command Mode
Description
active
RMON
Activates RMON history.
Before activating RMON history, check if your configuration is correct. After RMON history
is activated, you cannot change its configuration. If you need to change configuration, you
need to delete the RMON history and configure it again.
7.4.1.6
Deleting Configuration of RMON History
When you need to change a configuration of RMON history, you should delete an existing
RMON history.
To delete an RMON history, use the following command.
Command Mode
Description
no rmon-history
<1-65535>
Global
Deletes the RMON history of specified number, enter
the value for deleting.
7.4.1.7 Displaying
RMON
History
To display an RMON history, use the following command.
Command Mode
Description
show
running-config
rmon-
history
All
Shows a configured RMON history.
Always the last values will be displayed but no more than the number of the granted
buckets.