CLI
Management Guide
TigerAccess™ EE
118
SMC7824M/VSW
configuration is unnecessary on sysem, user can disable the system as FTP server.
To enable/disable the system of this switch as FTP server, use the following command.
Command Mode
Description
ftp server
{
enable
|
disable
} Global
Enables/disables the FTP server on the system.
(default: enable)
If the FTP server is disabled, the system software upgrade cannot be done via FTP server.
6.1.12
FTP Client address
You can specify several IP addresses to this switch. However, you can also specify one
IP address when this switch has access to FTP server as a client
To assign source IP address that uses when this switch has access to FTP server as a
client, use the following command.
Command Mode
Description
ftp bind-address
A.B.C.D
Specifies an IP address to bind it to be the ftp client.
no ftp bind-address
Global
Deletes a specified IP address as the ftp client
Please be careful that the FTP bind-address is also applied to TFTP server’s bind-
address.
6.1.13 System
Threshold
You can configure the system with various kinds of the system threshold such as CPU
load, traffic, temperature, etc. Using this threshold, the switch generates syslog mes-
sages, sends SNMP traps, or performs a relevant procedure.
6.1.13.1 CPU
Load
To set the threshold of CPU load, use the following command.
Command Mode
Description
threshold cpu
<21-100> {
5
|
60
|
600
} [<20-100> {
5
|
60
|
600
}]
Sets the threshold of CPU load in the unit of percent
(%).
21-100: CPU load high (default: 50)
20-100: CPU load low
5 | 60 | 600: time interval (second)
no threshold cpu
Global
Deletes the configured threshold of CPU load.
!