![SMC Networks 7724M/VSW - annexe 1 Manual Download Page 121](http://html1.mh-extra.com/html/smc-networks/7724m-vsw-annexe-1/7724m-vsw-annexe-1_manual_1299754121.webp)
CLI
Management Guide
TigerAccess™ EE
120
SMC7824M/VSW
When you set the threshold of fan operation,
START-TEMP
must be higher than
STOP-
TEMP
.
To show the configured threshold of fan operation, use the following command.
Command Mode
Description
show status fan
Enable/Global/Bridge
Shows the status and configured thresh-
old of fan operation.
6.1.13.4 System
Temperature
To set the threshold of system temperature, use the following command.
Command Mode
Description
threshold temp
<-40-100>
Sets the threshold of system temperature in the unit of
centigrade (°C).
-40-100: system temperature (default: 80)
no threshold temp
Global
Deletes a configured threshold of system temperature.
To show the configured threshold of system temperature, use the following command.
Command Mode
Description
show status temp
Enable
Global
Bridge
Shows the status and configured threshold of system
temperature.
6.1.13.5 System
Memory
To set the threshold of system memory in use, use the following command.
Command Mode
Description
threshold memory
<20-100>
Sets the threshold of system memory in the unit of
percent (%).
20-100: system memory in use
no threshold memory
Global
Deletes the configured threshold of system memory.
!
Summary of Contents for 7724M/VSW - annexe 1
Page 1: ......
Page 385: ...CLI Management Guide TigerAccess EE 384 SMC7824M VSW ...
Page 387: ......