![SMC Networks 7724M/VSW - annexe 1 Manual Download Page 147](http://html1.mh-extra.com/html/smc-networks/7724m-vsw-annexe-1/7724m-vsw-annexe-1_manual_1299754147.webp)
CLI
Management Guide
TigerAccess™ EE
146
SMC7824M/VSW
7.1.9.5 ADVA
Alarm
Severity
To set ADVA alarm severity, use the following command.
Command Mode
Description
snmp alarm-severity adva-fan-fail
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for sys-
tem temperature high.
snmp alarm-severity adva-if-misconfig
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for
wrong configuration.
snmp alarm-severity adva-if-opt-thres
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for traf-
fic threshold over for an Ethernet optical
interface.
snmp alarm-severity adva-if-rcv-fai
l {
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for fail-
ure to receive packets.
snmp alarm-severity adva-if-trans-fault
{
criti-
cal
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for fail-
ure to transmit packets.
snmp alarm-severity adva-if-sfp-mismatch
{
critical
|
major
|
minor
|
warning
|
intermedi-
ate
}
Sets ADVA severity of an alarm for SFP
module mismatched.
snmp alarm-severity adva-psu-fail
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for PSU
failure.
snmp alarm-severity adva-temperature
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for sys-
tem temperature high.
snmp alarm-severity adva-voltage-high
{
criti-
cal
|
major
|
minor
|
warning
|
intermediate
}
Sets ADVA severity of an alarm for input
voltage high.
snmp alarm-severity adva-voltage-low
{
critical
|
major
|
minor
|
warning
|
intermediate
}
Global
Sets ADVA severity of an alarm for input
voltage low.
To delete configured ADVA alarm severity, use the following command.
Command Mode
Description
no snmp alarm-severity adva-fan-fail
no snmp alarm-severity adva-if-misconfig
no snmp alarm-severity adva-if-opt-thres
no snmp alarm-severity adva-if-rcv-fail
no snmp alarm-severity adva-if-sfp-mismatch
no snmp alarm-severity adva-if-trans-fault
no snmp alarm-severity adva-psu-fail
no snmp alarm-severity adva-temperature
no snmp alarm-severity adva-voltage-high
no snmp alarm-severity adva-voltage-low
Global
Deletes configured ADVA alarm sever-
ity.