Simrad ER60 Operator manual
172
850-164692 / Rev.B
Description
Unit
Range
R/O
Parameter name
Vessel Distance
TransceiverMgr/
VesselDistance
Yes 0 to 100,000
nmi
Noise Estimate
ProcessingMgr/
<ChannelID>/
ChannelProcessingCommon/
NoiseEstimate
Yes 0 to --200
dB
ASYNCHRONOUS PARAMETERS
Vessel Speed
OwnShip/
Speed
No
0 to 100
m/s
Vessel Latitude
OwnShip/
Latitude
No
--90 to +90
deg
Vessel Longitude
OwnShip/
Longitude
No
--180 to +180
deg
Vessel Heave
OwnShip/
Heave
No
--100 to +100
m
Vessel Roll
OwnShip/
Roll
No
--90 to +90
deg
Vessel Pitch
OwnShip/
Pitch
No
--90 to +90
deg
Vessel Distance
OwnShip/
VesselDistance
No
0 to 100,000
nmi
Environment
Temperature
OwnShip/
EnvironmentData/
Temperature
No
--5 to +50
deg
Environment Salinity
OwnShip/
EnvironmentData/
Salinity
No
0 to 0.01
--
Environment Sound
Velocity
OwnShip/
EnvironmentData/
SoundVelocity
No
1,400 to 1,700
m/s
OPERATION MODE
Ping Start/Stop
OperationControl/
OperationMode
No
Last bit, 0=Stop, 1=Start
Ping Rate Mode
AcousticDeviceSynchroniser/
SyncMode
No
1=Interval, 2=Maximum,
32=Single step
Ping Interval
AcousticDeviceSynchroniser/
Interval
No
Larger than 10
msec
Save Raw Data On/Off SounderStorageManager/
SaveRawData
No
0=Off, 1=On
Summary of Contents for ER60