Simrad ER60 Operator manual
168
850-164692 / Rev.B
Targets integration
Subscription type string:
TargetsIntegration
This is a composite subscription where TS detection and
integration parameters must be set. The Sa value is taken only
from the accepted single echo trace inside the range.
Input
Parameters
Range
Default
Unit
sLayerType
(Surface, Bottom,Pelagic)
Surface
None
sIntegrationState
(Start,Stop)
Start
None
Update
(Update ping, Update accumulate)
Update ping
None
Range
(0,20000)
100
m
RangeStart
(0,20000)
10
m
Margin
(0,200)
1
m
SvThreshold
(--200,100)
--100
dB
MinTSValue
(--120,50)
--50
dB
MinEchoLength
(0,20)
0.8
None
MaxEchoLength
(0,20)
1.8
None
MaxGainCompensation (0,12)
6.0
dB
MaxPhaseDeviation
(0,100)
8.0
Phase steps
Output
struct StructIntegrationDataHeader
{
DWORDLONG dlTime;
};
struct StructIntegrationDataBody
{
double dSa;
// integrated value from single echo
// trace [m2/nmi2]
};
struct StructIntegrationData
{
StructIntegrationDataHeader
IntegrationDataHeader;
StructIntegrationDataBody
IntegrationDataBody;
};
Summary of Contents for ER60
Page 2: ......
Page 3: ...850 164692 ER60 Scientific echo sounder Operator manual...