Data interfaces
171
850-164692 / Rev.B
Description
Unit
Range
R/O
Parameter name
Transducer Depth
TransceiverMgr/
<ChannelID>/
TransducerDepth
No
0 to 10,000
m
Equivalent Beam Angle TransceiverMgr/
<ChannelID>/
EquivalentBeamAngle
No
--100 to 0
dB
Angle Sensitivity
Alongship
TransceiverMgr/
<ChannelID>/
AngleSensitivityAlongship
No
0 to 100
el.deg/
mec.deg
Angle Sensitivity
Athwartship
TransceiverMgr/
<ChannelID>/
AngleSensitivityAthwartship
No
0 to 100
el.deg/
mec.deg
Beam Width Alongship TransceiverMgr/
<ChannelID>/
BeamWidthAlongship
No
0 to 100
deg
Beam Width
Athwartship
TransceiverMgr/
<ChannelID>/
BeamWidthAthwartship
No
0 to 100
deg
Angle Offset Alongship TransceiverMgr/
<ChannelID>/
AngleOffsetAlongship
No
--10 to +10
deg
Angle Offset
Athwartship
TransceiverMgr/
<ChannelID>/
AngleOffsetAthwartship
No
--10 to +10
deg
Gain
TransceiverMgr/
<ChannelID>/
Gain
No
1 to 100
dB
Sa Correction
TransceiverMgr/
<ChannelID>/
SaCorrection
No
--10 to +10
dB
Ping Time
TransceiverMgr/
PingTime
Yes 2E64
100 ns
step
Vessel Latitude
TransceiverMgr/
Latitude
No
--90 to +90
deg
Vessel Longitude
TransceiverMgr/
Longitude
No
--180 to +180
deg
Vessel Heave
TransceiverMgr/
Heave
No
--100 to +100
m
Vessel Roll
TransceiverMgr/
Roll
No
--90 to +90
deg
Vessel Pitch
TransceiverMgr/
Pitch
No
--90 to +90
deg