Data interfaces
167
850-164692 / Rev.B
Integration
Subscription type string:
Integration
The update of Sa will be enabled by setting the Integration State
to start. If the update parameter is set to Update Ping, the new
Sa value is received for every ping.If the Update Accumulate is
set, the Sa is received only when the Integration State changes
to Stop.
Input
Parameters
Range
Default
Unit
LayerType
(Surface, Bottom,Pelagic)
Surface
None
IntegrationState
(Start,Stop)
Start
None
Update
(UpdatePing, UpdateAccumulate)
UpdatePin
g
None
Range
(0,20000)
100
m
RangeStart
(0,20000)
10
m
Margin
(0,200)
1
m
SvThreshold
(--200,100)
--100
dB
Ouput
struct StructIntegrationDataHeader
{
DWORDLONG dlTime;
};
struct StructIntegrationDataBody
{
double dSa;
// integrated value [m2/nmi2]
};
struct StructIntegrationData
{
StructIntegrationDataHeader
IntegrationDataHeader;
StructIntegrationDataBody IntegrationDataBody;
};
Example
Building an Integration Subscription String
Integration, ChannelID=<ChannelID>, State=Start,
Update=UpdatePing, Layertype=Surface, Range=100,
Rangestart=10, Margin=0.5, SvThreshold=-100.0