Parameter description
Introduction
The
ParameterServer
component can be used to access
asynchronous and ping based parameters. The parameters can be
“read”, “set” or subscribed to. A subscription will notify only
when the parameter’s value is changed.
The following is a list of the most relevant parameters. The
parameter name must be used when working with parameters as
described in the
Parameter Management
chapter.
Parameters identified as “read only” (R/O) can not be set. Some
of them, for example sensor parameters, can be set, but the new
value will immediately be overwritten if a live sensor is
connected.
Related topics
→
Parameter management, page 155
Descriptions
Description
Parameter name
R/O Range
Unit
PING BASED
List of ChannelID’s
TransceiverMgr/
Channels
Yes N/A
--
Frequency
TransceiverMgr/
<ChannelID>/
Frequency
Yes 1,000 to
1,000,000
Hz
Pulse Length
TransceiverMgr/
<ChannelID>/
PulseLength
No
0.000 to
0.065535
sec
Sample Interval
TransceiverMgr/
<ChannelID>/
SampleInterval
No
0.000010 to
0.065535
sec
Transmit Power
TransceiverMgr/
<ChannelID>/
TransmitPower
No
0 to 10,000
W
Absorption Coefficient
TransceiverMgr/
<ChannelID>/
AbsorptionCofficient
Yes 0.0 to 0.3
dB/m
Sound Velocity
TransceiverMgr/
<ChannelID>/
SoundVelocity
No
1,400 to 1,700
m/s
Transducer Name
TransceiverMgr/
<ChannelID>/
TransducerName
Yes N/A
--