Si5345-44-42-D-RM
82
Rev. 1.0
Si5345
The software tool version that created the register values that are downloaded at power up is represented by
TOOL_VERSION.
Part numbers are of the form:
Si<Part Num Base><Grade>-<Device Revision><OPN ID>-<Temp Grade><Package ID>
Examples:
Si5345C-A12345-GM.
Applies to a “base” or “blank” OPN (Ordering Part Number) device. These devices are factory pre-programmed
with the frequency plan and all other operating characteristics defined by the user’s ClockBuilder Pro project file.
Register 0x0005 Device Revision
Reg Address
Bit Field Type
Name
Description
0x0005
7:0
R
DEVICE_REV One ASCII character indicating the device revision level.
0 = A; 1 = B, etc.
Example Si5345C-
A
12345-GM, the device revision is “A”
and stored as 0
Register 0x0006–0x0008 TOOL_VERSION
Reg Address
Bit Field
Type
Name
Description
0x0006
3:0
R/W
TOOL_VERSION[3:0]
Special
0x0006
7:4
R/W
TOOL_VERSION[7:4]
Revision
0x0007
7:0
R/W
TOOL_VERSION[15:8]
Minor[7:0]
0x0008
0
R/W
TOOL_VERSION[15:8]
Minor[8]
0x0008
4:1
R/W
TOOL_VERSION[16]
Major
0x0008
7:5
R/W
TOOL_VERSION[13:17]
Tool. 0 for ClockBuilder Pro
Register 0x0009 Temperature Grade
Reg Address
Bit Field
Type
Name
Description
0x0009
7:0
TEMP_GRADE
Device temperature grading
0 = Industrial (-40° C to 85° C) ambient
conditions
Register 0x000A Package ID
Reg Address
Bit Field
Type
Name
Description
0x000A
7:0
PKG_ID
Package ID
0 = 9x9 mm 64 QFN