Si5345-44-42-D-RM
182
Rev. 1.0
Si5342
ClockBuilder Pro calculates the correct LOS register threshold trigger value for Input 3, given a particular frequency
plan.
ClockBuilder Pro calculates the correct LOS register clear threshold value for Input 0, given a particular frequency
plan.
ClockBuilder Pro calculates the correct LOS register clear threshold value for Input 1, given a particular frequency
plan.
ClockBuilder Pro calculates the correct LOS register clear threshold value for Input 2, given a particular frequency
plan.
Register 0x0034-0x0035 LOS3 Trigger Threshold
Reg Address
Bit Field
Type
Name
Description
0x0034
7:0
R/W
LOS3_TRG_THR
16-bit Threshold Value
0x0035
15:8
R/W
LOS3_TRG_THR
Register 0x0036-0x0037 LOS0 Clear Threshold
Reg Address
Bit Field
Type
Name
Description
0x0036
7:0
R/W
LOS0_CLR_THR
16-bit Threshold Value
0x0037
15:8
R/W
LOS0_CLR_THR
Register 0x0038-0x0039 LOS1 Clear Threshold
Reg Address
Bit Field
Type
Name
Description
0x0038
7:0
R/W
LOS1_CLR_THR
16-bit Threshold Value
0x0039
15:8
R/W
LOS1_CLR_THR
Register 0x003A-0x003B LOS2 Clear Threshold
Reg Address
Bit Field
Type
Name
Description
0x003A
7:0
R/W
LOS2_CLR_THR
16-bit Threshold Value
0x003B
15:8
R/W
LOS2_CLR_THR
Register 0x003C-0x003D LOS3 Clear Threshold
Reg Address
Bit Field
Type
Name
Description
0x003C
7:0
R/W
LOS3_CLR_THR
16-bit Threshold Value
0x003D
15:8
R/W
LOS3_CLR_THR