Si5345-44-42-D-RM
Si5344
Rev. 1.0
157
14.4.4. Page 3 Registers Si5344
The N dividers are interpolative dividers that are used as output dividers that feed into the R dividers. ClockBuilder
Pro calculates the correct values for the N-dividers.
This bit is provided so that all of the N0 divider bits can be changed at the same time. First, write all of the new
values to the divider; then, set the update bit.
Register 0x0302-0x0307 N0 Numerator
Reg Address
Bit Field
Type
Name
Description
0x0302
7:0
R/W
N0_NUM
44-bit Integer Number
The N0 value is N0_NUM/N0_DEN
0x0303
15:8
R/W
N0_NUM
0x0304
23:16
R/W
N0_NUM
0x0305
31:24
R/W
N0_NUM
0x0306
39:32
R/W
N0_NUM
0x0307
43:40
R/W
N0_NUM
Register 0x0308-0x030C N0 Denominator
Reg Address
Bit Field
Type
Name
Description
0x0308
7:0
R/W
N0_DEN
32-bit Integer Number
The N0 value is N0_NUM/N0_DEN
0x0309
15:8
R/W
N0_DEN
0x030A
23:16
R/W
N0_DEN
0x030B
31:24
R/W
N0_DEN
0x030C
0
R/W
N0_UPDATE
Set this bit to update the N0 divider.
Table 54. Registers that Follow the N0_NUM and N0_DEN Definitions
Register Address
Description
Size
Same as Address
0x030D-0x0312
N1 Numerator
44-bit Integer Number
0x0302-0x0307
0x0313-0x0316
N1 Denominator
32-bit Integer Number
0x0308-0x030B
0x0317
N1_UPDATE
one bit
0x030C
0x0318-0x031D
N2 Numerator
44-bit Integer Number
0x0302-0x0307
0x031E-0x0321
N2 Denominator
32-bit Integer Number
0x0308-0x030B
0x0322
N2_UPDATE
one bit
0x030C
0x0323-0x0328
N3 Numerator
44-bit Integer Number
0x0302-0x0307
0x0329-0x032C
N3 Denominator
32-bit Integer Number
0x0308-0x030B
0x032D
N3_UPDATE
one bit
0x030C