Si5345-44-42-D-RM
198
Rev. 1.0
Si5342
Note that changing this register during operation may cause indefinite loss of lock unless the guidelines in "4.2.2.
Revision D" on page 16 are followed.
The M-divider numerator and denominator are set by ClockBuilder Pro for a given frequency plan. Note that
changing this register during operation may cause indefinite loss of lock unless the guidelines in "4.2.2. Revision D"
on page 16 are followed.
Register 0x0234 P3 Factional Division Enable
Reg Address
Bit Field
Type
Setting Name
Description
0x0234
3:0
R/W
P3_FRACN_MODE
P3 (IN3) input divider fractional
mode. Must be set to 0xB for proper
operation.
0x0234
4
R/W
P3_FRAC_EN
P3 (IN3) input divider fractional
enable
0: Integer-only division.
1: Fractional (or Integer) division.
Register 0x0235-0x023A MXAXB Divider Numerator
Reg Address
Bit Field
Type
Setting Name
Description
0x0235
7:0
R/W
MXAXB_NUM
44-bit Integer Number
0x0236
15:8
R/W
MXAXB_NUM
0x0237
23:16
R/W
MXAXB_NUM
0x0238
31:24
R/W
MXAXB_NUM
0x0239
39:32
R/W
MXAXB_NUM
0x023A
43:40
R/W
MXAXB_NUM
Register 0x023B-0x023E MXAXB Divider Denominator
Reg Address
Bit Field
Type
Setting Name
Description
0x023B
7:0
R/W
MXAXB_DEN
32-bit Integer Number
0x023C
15:8
R/W
MXAXB_DEN
0x023D
23:16
R/W
MXAXB_DEN
0x023E
31:24
R/W
MXAXB_DEN