SIGNAMAX a.s.
Office: Vlarska 22, 627 00 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
84
Warm Start Trap: Enable or disable the Managed Switch to send a trap when the Managed
Switch warm starts.
Authentication Failure Trap: Enable or disable the Managed Switch to send authentication
failure trap after any unauthorized users attempt to login.
Port Link Up/Down Trap: Enable or disable the Managed Switch to send port link up/link
down trap.
Broadcast Storm Trap:
Enable or disable broadcast storm trap sending from the Managed
Switch when broadcast packets reach the upper limit.
Upper Limit: Maximum broadcast packets number per second. The broadcast storm trap
will be sent when the Managed Switch exceeds the specified limit.
System Power Down Trap: Send a trap notice while the Managed Switch is power down.
Case Fan Trap: Enable or disable the Managed Switch to send a trap when fan is not
working or failed.
SFP Abnormality Tray: Enable or disable the Managed Switch to send SFP abnormality
trap.
4.3.8 Mal-attempt Log Configuration
Click the option Mal-attempt Log Configuration from the Network Management menu
and then the following screen page appears.
When DHCP Snooping filters unauthorized DHCP packets on the network, the Mal-attempt
Log will allow the Managed Switch to send event notification message to Log server.
Log Server: Enable or disable Mal-attempt log function.
SNTP Status: View-only field that shows the SNTP server status.
Log Server IP-1: Specify the default Log server IP address.
Log Server IP-2: Specify the second Log server IP address. When the default Log Server is
down, the Managed Switch will automatically contact the second or third Log server.