SIGNAMAX a.s.
Office: Vlarska 22, 627 00 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
117
1. QoS Port Configuration: To set up each port’s QoS default class, QCL, Priority,
Queuing Mode, Queue Weighted.
2. QoS Control List: To create, edit or delete QCL settings.
3. QoS Rate Limiters: To configure each port’s Policer and Shaper Rate.
4. Storm Control: To enable or disable Unicast, Broadcast and Multicast Storm Control.
4.4.8.1 QoS Port Configuration
Select the option QoS Port configuration from the QoS Configuration menu and then the
following screen page appears.
Configure Default Class:
Click the pull-down menu to choose the class level “Low”, “Normal”, “Medium” or “High”.
The default class level of each port is “Low”.
Configure QCL:
A QCL number is assigned to each port based on the information in the QCL table. Please