SIGNAMAX a.s.
Office: Vlarska 22, 627 00 Brno, CZ
T:+420 533 338 854 l F:+420 533 338 883 l www.signamax.eu
34
description <description>
Enter the description for this user account.
<description>: Enter the description for this
user account of up to 35 alphanumerical
characters.
ip <enable | disable>
To enable or disable IP security function of
this user account.
ip_addr <ip_addr>
Enter the IP address for IP security function.
<ip_addr>: Enter the IP address.
level <administrator |
read_and_write | read_only
| access_denied>
Set up the console level for this user
account.
<administrator | read_and_write |
read_only | access_denied>: Four
operation privileges are available in the
Managed Switch.
Administrator: Full access right includes
maintaining user account & system
information, loading factory settings, etc.
Read & Write: Full access right but cannot
modify user account & system information
and load factory settings.
Read Only: Allow to view only.
Access Denied: Completely forbidden for
access.
NOTE: If you would like to edit the settings
of a user account, you can enter the
command user user id under the SWH#.
For example:
If you want to edit settings of the user
account “mis2”, you can use the following
commands to enter the editing mode.
SWH#user mis2
SWH(user_mis2)#
mode <enable | disable>
To enable or disable RADIUS Authentication.
secret <secret>
The word or characters to encrypt data sent
to RADIUS server. The word or characters
are up to 31 characters.
SWH(user-radius)#
port <port>
The RADIUS service port on RADIUS
server.
<port>: The port number is between 1025
and 65535.
For example:
SWH(user-radius)#port 1812