background image

 

22 PORTS 10/100/1000BASE-T 

MANAGEMENT ETHERNET SWITCH 

W/2 COMBO SFP SLOTS UPLINK 

 

Model

:

 

500-7622GE2GS

 

Summary of Contents for 500-7622GE2GS

Page 1: ...0 22 PORTS 10 100 1000BASE T MANAGEMENT ETHERNET SWITCH W 2 COMBO SFP SLOTS UPLINK Model 500 7622GE2GS...

Page 2: ...lation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the inter...

Page 3: ...5 1 Backup command mode 23 2 5 2 Console command mode 24 2 5 3 IP command mode 24 2 5 4 Service command mode 25 2 5 5 Syslog command mode 29 2 5 6 System command mode 29 2 5 7 Time server command mod...

Page 4: ...97 4 4 6 MAC Address Management 100 4 4 7 VLAN Configuration 102 4 4 8 QoS Configuration 116 4 4 9 DSCP Remark 122 4 4 10 Port Mirroring 124 4 4 11 IGMP Snooping 125 4 4 12 Static Multicast Configurat...

Page 5: ...SIGNAMAX a s Office Vlarska 22 627 00 Brno CZ T 420 533 338 854 l F 420 533 338 883 l www signamax eu 4 4 7 Save Configuration 174 4 8 Reset System 174 APPENDIX A 175 APPENDIX B 176 APPENDIX C 181...

Page 6: ...ure your Managed Switch The readers of this manual should have knowledge about their network typologies and about basic networking concepts so as to make the best of this user s manual and maximize th...

Page 7: ...nt especially for the first time use of the Managed Switch to set up the needed IP can be done through one of the 10 100Base TX 8 pin RJ 45 ports located at the front panel of the Managed Switch Direc...

Page 8: ...After you have decided how to manage your Managed Switch you are required to connect cables properly determine the Managed switch IP address and in some cases install MIB shipped with your Managed Sw...

Page 9: ...ent Switch and the PC By connecting this DB 9 port it allows you to configure check the status of Management Switch even when the network is down IP Addresses IP addresses have the format n n n n The...

Page 10: ...Management Information Bases is provided for managing the Managed switch through the SNMP based network management system You must install the private MIB into your SNMP based network management syst...

Page 11: ...especially when the network is down and the switch cannot be reached by any other means You also need the Local Console Management to setup the Switch network configuration for the first time You can...

Page 12: ...e Interface CLI of this Managed Switch is divided into three different modes After you enter the required username and password you start from the User mode The commands available depend on which mode...

Page 13: ...ile in User mode enter exit command Username Exit from current mode help While in User mode enter help command SWH Show available commands that can be used in User mode history While in User mode ente...

Page 14: ...ile in Enable mode enter the history command SWH List commands that have been used ip While in Enable mode enter the ip command SWH ip Configure IP addresses of the Managed Switch logout While in Enab...

Page 15: ...g Save configuration to the Managed Switch s flash memory and show currently operating configurations show While in Enable mode enter the show command or enter the show command and followed by the com...

Page 16: ...d SWH config mirror Set up target port for mirroring mvr When in Config mode enter the mvr command SWH config mvr Configure Multicast VLAN Registration MVR settings port When in Config mode enter the...

Page 17: ...characters then enter the question mark List all commands similar to incomplete characters Press the direction or key Scroll through the command history Enter unique part of a command and press TAB ke...

Page 18: ...n User mode Company Name This shows the company name or related information System Object ID This shows the predefined System OID System Contact This shows the system contact information System Name T...

Page 19: ...nds available Show a Command s Current Settings In User Enable and Config mode you can type show and followed by the command listed above to view its current setting For example if you type show qos i...

Page 20: ...ured setting of time out function 2 3 4 Listing Command After entering the question mark at the prompt line the screen will show a list of commands available for each command mode The following explai...

Page 21: ...quired parameters or values are in angle brackets Optional parameters or values are in square brackets port_list port_list allows you to enter several discontinuous port number separating by a comma f...

Page 22: ...ot up message Enable Mode Password Enable mode is password protected When you try to enter Enable mode a password prompt will appear to request the user to provide the legitimate passwords Enable mode...

Page 23: ...lay the command history logout Logout from the Managed Switch ping Allow users to ping a specified network device show Show a list of commands or show the current setting of each listed command 2 5 En...

Page 24: ...rrent mode exit show Show Backup Settings show SWH backup Prompt Command Parameter Description auto backup ftp tftp server ip username password file directory 0 23 o clock To configure auto backup set...

Page 25: ...de SWH console SWH console Command Purpose Description Usage time out Set Time Out time out secs exit Exit from current mode exit show Show Console Settings show SWH console Prompt Command Parameter D...

Page 26: ...hich is responsible for the delivery of the IP packets sent by the Switch This address is required when the Switch and the network management station are on different networks or subnets The default v...

Page 27: ...e name of the community is up to 20 alphanumeric characters For example SWH snmp community add myswitch SWH snmp community delete community To delete a community that is already added to the Managed s...

Page 28: ...ormation and load factory settings Read Only Allow to view only Access Denied Completely forbidden for access NOTE 1 When the community browses the Managed Switch without proper access right the Manag...

Page 29: ...trap dest_trap id community community Enter the community name community Enter the community name of up to 20 characters cold start enable disable To enable or disable the Managed Switch to send a tra...

Page 30: ...syslog server 3 ip_addr3 Set up the third syslog server IP ip_addr3 Specify the third syslog server IP address 2 5 6 System command mode SWH system SWH system Command Purpose Description Usage company...

Page 31: ...minutes time zone Set Time Zone time zone time_zone day saving Set Daylight Saving day saving enable disable offset Set Offset offset hour exit Exit from current mode exit show Show Time Server Settin...

Page 32: ...SIGNAMAX a s Office Vlarska 22 627 00 Brno CZ T 420 533 338 854 l F 420 533 338 883 l www signamax eu 31...

Page 33: ...To restore configuration via FTP or TFTP server ftp ftp Specify whether you would like to restore a configuration file via FTP or TFTP serverip Enter the IP address of the FTP or TFTP server username...

Page 34: ...s_denied Four operation privileges are available in the Managed Switch Administrator Full access right includes maintaining user account system information loading factory settings etc Read Write Full...

Page 35: ...ccess right includes maintaining user account system information loading factory settings etc Read Write Full access right but cannot modify user account system information and load factory settings R...

Page 36: ...e In Configuration mode you can set up advanced switching functions such as QoS VLAN Remarking Enter the configure or config for short command after SWH directory and type in to view a list of availab...

Page 37: ...SIGNAMAX a s Office Vlarska 22 627 00 Brno CZ T 420 533 338 854 l F 420 533 338 883 l www signamax eu 36 show Show current settings show SWH config...

Page 38: ...ctions SKA settings multicast Configure static multicast settings switch Set up acceptable frame size and address learning etc vlan Set up VLAN mode and VLAN configuration lldp Set up LLDP Link Layer...

Page 39: ...send a copy of packets to the specified port For example SWH config acl port copy 1 4 10 15 18 19 disable rate lim port_list disable 1 14 To enable or disable rate limiter of the specified ports and s...

Page 40: ...dless of its ACL ID For example if the ACL rule with ACL ID 5 is entered before the ACL rule with ACL ID 3 is entered then the ACL rule with ACL ID 5 will be looked up first before ACL ID 3 any policy...

Page 41: ...ses Or enter the specific source MAC address dest_mac Specify Any to apply ACL rule to any destination MAC addresses Specify uc to apply ACL rule to unicast traffic Specify mc to apply ACL rule to mul...

Page 42: ...rk address and subnet mask arp_smac_match This is to configure whether ARP source MAC sent and received are matched or not Specify any to denote both a match and not a match 0 to denote not a match 1...

Page 43: ...onal values specific to ICMP UDP or TCP will be set to any source_ip This is source IP filtering function Specify any to filter frames from any sender IP addresses Or specify either a host IP address...

Page 44: ...ent defined codes source_ip This is source IP filtering function Specify any to filter frames from any sender IP addresses Or specify either a host IP address or a network address and subnet mask dest...

Page 45: ...u would like to filter a range of port numbers you need to specify a destination port range from 0 to 65535 source_ip This is source IP filtering function Specify any to filter frames from any sender...

Page 46: ...ost IP address or a network address and subnet mask ip_ttl Specify 0 to indicate that the TTL field in IPv4 header is 0 If the value in TTL field is not 0 use 1 to indicate that You can also specify a...

Page 47: ...ll receive a copy of packets rate lim disable 1 14 Configure the rate limiter function disable 1 14 Disable rate limiter function or specify a rate limiter ID shutdown enable disable To enable or disa...

Page 48: ...12 aggr_id Specify an aggregation ID from 1to 13 For example SWH config aggr add 1 4 10 15 19 10 delete aggr_id Delete an aggregation ID aggr_id Specify the aggregation ID that you would like to delet...

Page 49: ...ort group to negotiate adjustments and make changes dynamically one end of the connection must have active LACP ports For example SWH config aggr lacp role 1 4 10 15 18 19 active 2 6 3 Dot1x command m...

Page 50: ...e client to be authorized by the authentication server Accesses from clients that are not dot1x aware will be denied For example SWH config dot1x state 1 4 10 15 18 19 auto SWH config dot1x authentic...

Page 51: ...nt ID is from the entry registered in Segment option For Example SWH config profile add myprofile 2 SWH config profile delete profile_name To delete a registered profile Edit details of an existing pr...

Page 52: ...Fast Leave fast leave enable disable exit Exit from current mode exit show Show IGMP Settings show SWH config igmp Prompt Command Parameter Description mode enable disable To enable or disable IGMP fu...

Page 53: ...ig mac Prompt Command Parameter Description SWH config mac learning port_list auto disable To set up each port s MAC learning function port_list Specify a port number or multiple port numbers with the...

Page 54: ...e Delete MVR del vid group Enter Group Cmd Mode group exit Exit from current mode exit show Show MVR Settings show SWH config mvr Prompt Command Parameter Description mode enable disable To enable or...

Page 55: ...untag 2 6 9 Port command mode Prompt Command Parameter Description SWH config port all port_list state enable disable port all port_list media copper fiber port all port_list type manual auto negotiat...

Page 56: ...er QCL Cmd Mode qcl class Set Default Class class port_list type tagpriority Set Tag Priority tag port_list pri mode Set Mode mode port_list type weight Set Weight weight port_list weight rate limit E...

Page 57: ...his QoS rule betwee 0x600 and FFFF vid vid 1 4094 Specify the VID to this QoS rule port udp_tcp_port 0 65535 Specify the UDP or TCP port number between 0 65535 dscp dscp0 63 Specify a DSCP value betwe...

Page 58: ...ict indicates that services to the egress queues are offered in the sequential order and all traffic with higher priority queues are transmitted first before lower priority queues are serviced Weighte...

Page 59: ..._rate disable 1 2 4 8 16 32 64 128 256 512 1k 2k 4k 8k 16k 32k 64k 128k 256k 512k 1024k For example SWH config qos storm multicast disable SWH config qos storm broadcast packet_rate To set up broadcas...

Page 60: ...elected port s port_list Specify a port number or multiple port numbers with the format 5 7 8 9 12 or 5 7 9 12 enable disable To enable or disable 802 1p of the selected ports For example SWH config r...

Page 61: ...lowest cost path is always used unless the other path is down If you have multiple bridges and interfaces then you may need to adjust the priorities to achieve optimized performance The Managed Switch...

Page 62: ...ach port s priority port_list Specify a port number or multiple port numbers with the format 5 7 8 9 12 or 5 7 9 12 priority 0 0 1 16 2 32 3 48 4 64 5 80 6 96 7 112 8 128 9 144 10 160 11 176 12 192 13...

Page 63: ...o turn on Ports set as forced_false will be forced to turn off Auto will detect the status automatically 2 6 13 SKA command mode SWH config ska SWH config ska Command Purpose Description Usage opt82 E...

Page 64: ...fy authorized access information for each port port_list 1 22 unlimited dhcp fix ip Three options are available Unlimited Non Limited Static IP or DHCP assigns IP DHCP DHCP server assigns IP address F...

Page 65: ...gnamax eu 64 add ip mask vlan_ip port Add a static IP ip Specify a static IP address mask Specify a subnet mask vlan_ip 1 4094 port 1 22 SWH config ska static ip delete ip mask vlan_ip port Delete a s...

Page 66: ...ast add 224 0 1 0 4094 22 SWH config multicast delete ip addr vlan_id port To delete a registered static multicast ip addr Specify a multicast address ranging from 224 0 1 0 238 255 255 255 vlan_id 1...

Page 67: ...180C2000000 to 0180C200000F will be filtered or dropped 20 2F filter not filter Select either Not Filter or Filter When Filter is selected packets from the address ranging from 0180C2000020 to 0180C20...

Page 68: ...VLAN For example SWH config vlan dot1q delete 1 Edit details of a dot1q VLAN entry If you would like to modify an existing VLAN entry you can enter dot1q VID after SWH config vlan For example enter SW...

Page 69: ...rt numbers as the management ports with the format 5 7 8 9 12 or 5 7 9 12 aware Enable or disable VLAN aware function cpu_vid Specify an existing VID For example SWH config vlan mgt vlan 1 4 10 15 18...

Page 70: ...port_list type holdtime Set Receiver Hold Time TTL holdtime 1 3600 interval Set Sending packet interval 1 180 packets Set Sending Packets Per packets 1 16 initdelay Set Delay initialization initdelay...

Page 71: ...l sec Specify the time interval for updated LLDP packets to be sent sec 1 180 seconds For example SWH config lldp interval 5 packets packet Specify the amount of packets that are sent in each discover...

Page 72: ...ices NMS provide the bulk of the processing and memory resources required for the complete network management SNMP Manager often composed by desktop computer work station and software program such lik...

Page 73: ...to manage the Managed Switch through a Web browser Use the RS 232 DB 9 console port or one of the 10 100 1000Base TX RJ 45 ports as the temporary RJ 45 Management console port to set up the assigned I...

Page 74: ...ve an existing user 3 Network Management Set up or view the IP address and related information of the Managed Switch required for network management applications 4 Switch Management Set up switch port...

Page 75: ...lation to your network for example Backbone 1 This name is mainly used for reference only System Location Enter a brief description of the Managed Switch location up to 55 alphanumeric characters Like...

Page 76: ...rate the Managed Switch Any users who want to operate the Managed Switch need to register into the user list first To view or change current registered users select User Authentication from the Main M...

Page 77: ...security function If enabled the user can access the Managed Switch only through the management station which has exact IP address specified in IP address field below If disabled the user can access t...

Page 78: ...eadme txt file on the disc provided with this product Secret Key The word to encrypt data of being sent to RADIUS server RADIUS Port The RADIUS service port on RADIUS server Retry Time The number of t...

Page 79: ...8 Mal attempt Log Configuration Set up the Mal attempt Log server s configuration 4 3 1 Network Configuration Click the option Network Configuration from the Network Management menu and then the foll...

Page 80: ...le for the delivery of the IP packets sent by the Managed Switch This address is required when the Managed Switch and the network management station are on different networks or subnets The default va...

Page 81: ...S 232 setting view only field Word Length 8 RS 232 setting view only field Flow Control None RS 232 setting view only field Telnet Port Specify the desired TCP port number for the Telnet console The d...

Page 82: ...on It is a way of getting more daytime hour s by setting the time to be hour s ahead in the morning Daylight Saving Time Offset Click the pull down menu to select the time offset of daylight saving ti...

Page 83: ...ity name up to 35 alphanumeric characters This is mainly for reference only IP Security Click the pull down menu to enable or disable the IP security function If enabled Community may access the Manag...

Page 84: ...function of sending trap to the specified destination Destination Enter the specific IP address of the network management system that will receive the trap Community Enter the community name of the n...

Page 85: ...ystem Power Down Trap Send a trap notice while the Managed Switch is power down Case Fan Trap Enable or disable the Managed Switch to send a trap when fan is not working or failed SFP Abnormality Tray...

Page 86: ...c 3 Link Aggregation Set up port trunk and LACP port configuration 4 Rapid Spanning Tree Set up RSTP switch settings aggregated port settings physical port settings etc 5 802 1X Configuration Set up t...

Page 87: ...frame size is 9600bytes MAC Address Aging Time Specify MAC Address aging time between 0 and 1048575 seconds SFP Safety Temperature Enter the specific temperature for the Managed Switch to detect the S...

Page 88: ...ed for future standardization 0180C2000008 All Provider Bridges 0180C2000009 C Reserved for future standardization 0180C200000D Provider Bridge GVRP Address 0180C200000E 802 1AB Link Layer Discovery P...

Page 89: ...up a high speed backbone network that transfers much more data than any one single port or device can deliver without replacing everything and buying new hardware For most backbone installations it i...

Page 90: ...re two fields for you to set up packets according to operations Source MAC Address Enable or disable packets according to source MAC address Destination MAC Address Enable or disable packets according...

Page 91: ...ame speed and should be configured as full duplex 4 4 3 3 LACP Port Configuration The Managed Switch supports dynamic Link Aggregation Control Protocol LACP which is specified in IEEE 802 3ad Static t...

Page 92: ...the pull down menu of Select Setting Ports in an aggregated link group must have the same LACP port Key In order to allow a port to join an aggregated group the port Key must be set to the same value...

Page 93: ...ich are not part of that tree leaving a single active path between any two network nodes Multiple active paths between network nodes cause a bridge loop Bridge loops create several problems First the...

Page 94: ...n RSTP Switch Settings from the Rapid Spanning Tree menu and then the following screen page appears System Priority Each interface is associated with a port number in the STP code And each switch has...

Page 95: ...ter media and higher values assigned to ports with slower media 0 means auto generated path cost Priority Choose a value between 0 and 240 to set the priority for the port interface A higher priority...

Page 96: ...ical Port Settings Click the option RSTP Physical Port Settings from the Rapid Spanning Tree menu and then the following screen page appears Configure Port State Select State from the pull down menu o...

Page 97: ...gnamax eu 96 Select Priority from the pull down menu of Select Setting You can choose Port Priority value between 0 and 240 The default value is 0 Configure Port Edge Select Edge from the pull down me...

Page 98: ...to clients connecting to a VLAN clients that are 802 1X complaint should successfully authenticate with the authentication server Initially ports are in the authorized state which means that ingress a...

Page 99: ...ent and the authentication server In other words the Managed Switch requests identifying information from the client verifies that information with the authentication server and relays the response to...

Page 100: ...d By default all ports are set to Authorized Unauthorized This forces the Managed Switch to deny access to all clients either 802 1X aware or 802 1X unaware Auto This requires 802 1X aware clients to...

Page 101: ...e following screen page appears 1 MAC Table Learning To enable or disable learning MAC address function 2 Static MAC Table Configuration To create edit or delete Static MAC Table setting 4 4 6 1 MAC T...

Page 102: ...AC security list Click New to add a new MAC address entity and then the following screen page appears Click Edit to view and edit the selected MAC address entity Click Delete to remove a MAC address e...

Page 103: ...e connections Stations can be moved to another VLAN and thus communicate with its members and share its resources simply by changing the port VLAN settings from one VLAN to another This allows VLAN to...

Page 104: ...will not occupy too much available bandwidth as well as provide a higher level security between segments of internal networks Introduction to 802 1Q frame format Preamble SFD DA SA Type LEN PAYLOAD FC...

Page 105: ...fic Packets will not be forwarded unless they belong to the VLANs that the port is one of the members The differences between Ingress and Egress configurations can provide network segmentation Moreove...

Page 106: ...nation MAC address is unknown the frame will be flooded to all ports in the VLAN Tagging Every port on an 802 1Q compliant switch can be configured as tagging or un tagging Ports with taggings Enable...

Page 107: ...VID is not used to make packet forwarding decisions the VID is VLAN aware switches must keep a table so as to relate PVIDs within the Switch to VIDs on the network The Managed Switch will compare the...

Page 108: ...common thing about these two locations is that they have the same VLAN ID of 20 called C VLAN Customer VLAN Since customer traffic will be routed to service provider s backbone there is a possibility...

Page 109: ...To create edit or delete 802 1Q Tag VLAN settings 2 Tag VLAN Setting To set up VLAN Aware Ingress Filter Frame Type Port VLAN ID Port Egress Mode 4 4 7 4 1 Configure VLAN The following screen page ap...

Page 110: ...ing for all ports is Disable VLAN Aware Disable The ingress frame will always be tagged with a PVID If the incoming frame already has a VID or C tag tag then it will be doubled tagged a PVID will be a...

Page 111: ...rom a port that belongs to one of the existing VID entries is allowed to pass through otherwise they will be dropped before checking the entire VID table Ingress Filter Disable When disabled incoming...

Page 112: ...from the pull down menu of Select Setting Frame Type Two frame types are available these are All and Tagged The default setting is All to all ports All All means that the port will send and receive b...

Page 113: ...Configure Port Egress Mode The following screen page appears if you choose Tag VLAN Settings and then select Port Egress Mode from the pull down menu of Select Setting Port Egress Mode Two frame type...

Page 114: ...be forwarded untagged If the frame is double tagged then the outer tag s tag will be removed 4 4 7 4 7 Configure Management VLAN The following screen page appears if you choose Tag VLAN Settings and...

Page 115: ...Configure Q in Q This section provides an example on how to configure Q in Q using 802 1q function Follow the steps described blow or use them as reference to set up configurations that are suitable...

Page 116: ...00 Brno CZ T 420 533 338 854 l F 420 533 338 883 l www signamax eu 115 Step 2 Set up VLAN Aware Set Port 1 s VLAN Aware to Disable and Port 23 s to Enable Step 3 Set up Port VLAN ID Set Port 1 s Port...

Page 117: ...ome this challenge Quality of Service QoS is applied throughout the network This ensures that network traffic is prioritized according to specified criteria and receives preferential treatments QoS en...

Page 118: ...port s Policer and Shaper Rate 4 Storm Control To enable or disable Unicast Broadcast and Multicast Storm Control 4 4 8 1 QoS Port Configuration Select the option QoS Port configuration from the QoS C...

Page 119: ...ll down menu for CoS Class of Service priority tag values The default value is 0 The default 802 1p settings are shown in the following table Priority Level Normal Low Low Normal Medium Medium High Hi...

Page 120: ...r each port 4 4 8 2 QoS Control List The following screen page appears if you choose QoS Priority Configuration and then select QoS Control List QCL Select a QCL number 1 24 QCE Type View only field t...

Page 121: ...N ID as your preferred QCE Type you can further specify VLAND ID value from 1 to 4094 TCP UDP Port When you choose UDP TCP Port as your preferred QCE Type you can further specify TCP UDP Port by selec...

Page 122: ...rity Configuration menu and then the following screen page appears Configure Policer Rate This allows users to specify each port s inbound bandwidth The excess traffic will be dropped Specifying 0 is...

Page 123: ...ts exceeding the specified threshold will then be dropped Three options of frame traffic are provided to allow users to enable or disable the storm control Unknown Unicast Rate Enable or disable unkno...

Page 124: ...ble DSCP remarking for each port The default setting is disabled Configure 802 1p Remark Select 802 1p Remark from the pull down menu of Select Setting This allows you to enable or disable 802 1p rema...

Page 125: ...Port and enable traffic monitoring select the option Port Mirroring from the Switch Management menu and then the following screen page appears Source Port Choose Y enable or N disable from the pull do...

Page 126: ...n multicast group from a host the switch adds the host s port number to the multicast list for that group When the switch hears an IGMP Leave it removes the host s port from the table entry IGMP snoop...

Page 127: ...rwarding mode for unregistered not joined IP multicast traffic The traffic will flood when enabled However the traffic will forward to router ports only when disabled Query Interval The Query Interval...

Page 128: ...rmine which hosts want to receive the multicast traffic Querying When enabled the port in VLAN can serve as the Querier which is responsible for asking hosts whether they want to receive multicast tra...

Page 129: ...mber is 400 Segment ID Specify a number from 1 400 for a new ID Segment Name Enter an identification name This field is limited to 20 characters IP Range Specify the multicast streams IP range for the...

Page 130: ...al This shows the number of total IPMC Profiles that are registered Max This shows the maximum number available for IPMC Profile The maximum number is 60 Profile Name Enter an identification name This...

Page 131: ...setting is Off which is disabled Port View only field that shows the port number that is currently configured IPMC Profile In IGMP filtering it only allows information specified in IPMC Profile fields...

Page 132: ...multicast configuration The default maximum number is 128 IP Address Specify the multicast stream source IP address VLAN Specify a VLAN ID for multicast stream Forwarding port Select a port number fo...

Page 133: ...VLANs but they should not belong to the multicast VLAN Do not configure MVR on private VLAN ports MVR can coexist with IGMP snooping on a switch MVR data received on an MVR receiver port is not forwa...

Page 134: ...wing screen page appears Click Edit to edit MVR settings Use Delete to remove a current MVR VLAN ID Current Total Max Multicast Nums View only field Current This shows the number of current registered...

Page 135: ...New to register a new MVR Group and then the following screen page appears Click Edit to edit and view the MVR Group settings Click Delete to remove a current MVR Group Current Total Max Group Nums Vi...

Page 136: ...of DHCP Relay Agent Information adds Agent Information field to the Option 82 field that is in the DHCP headers of client DHCP request frames Guidelines Enable DHCP Option 82 Relay Agent global setti...

Page 137: ...ect the option DHCP Option 82 Settings from the SKA Configuration menu and then the following screen page appears Opt82 Port Setting Relay Agent To enable or disable DHCP Option 82 Relay Agent Global...

Page 138: ...a 22 627 00 Brno CZ T 420 533 338 854 l F 420 533 338 883 l www signamax eu 137 Trust Port Setting Trust Port Select V if you would like ports to become trust ports The trusted ports will not discard...

Page 139: ...is marked as Opt 82 port A If a DHCP request is with Opt82 Agent information and then the Managed Switch will drop it because it is not marked as a trust port B If a DHCP request is without Opt82 Age...

Page 140: ...80 259200 Seconds Port Isolation Enable or disable port isolation function If port isolation is set to enable the customer port port 1 22 can t communicate to each other IPv6 Filter Enable or disable...

Page 141: ...rrent registered Static IP address es Total This shows the total number of registered Static IP address es Max This shows the maximum number available for Static ID address registration IP address Spe...

Page 142: ...ion process is complete If you connect clients to the Managed Switch before you complete Step 1 2 please disconnect your clients and then connect your clients to the Managed Switch again to enable the...

Page 143: ...Select a policy ID from the pull down menu A port can only use one policy ID however a policy ID can apply to many ports Action Deny or permit the action Rate Limiter Disable or enable rate limiter W...

Page 144: ...iter is enabled in ACL Ports Configuration rate of each Rate Limiter can be further specified Rate pps Select the rate for each Rate Limiter ID 4 4 15 3 ACL Configuration Click New to add a new ACL co...

Page 145: ...a port number as the ingress port Frame Type Select Any Ethernet Type ARP or IPv4 as the desired frame type Options displayed in MAC and VLAN parameters will vary according to the frame type you selec...

Page 146: ...tination MAC filtering Select Any to filter any kind of traffic Select UC to filter unicast traffic Select MC to filter multicast traffic Select BC to filter broadcast traffic VLAN Parameters VLAN ID...

Page 147: ...ation MAC address Select Any to filter any kind of traffic Select UC to filter unicast traffic Select MC to filter multicast traffic Select BC to filter broadcast traffic DMAC Value Specify a destinat...

Page 148: ...C MC or BC for destination MAC filtering Select Any to filter any kind of traffic Select UC to filter unicast traffic Select MC to filter multicast traffic Select BC to filter broadcast traffic VLAN P...

Page 149: ...atch and not a match RARP DMAC Match Select 0 to indicate that the THA Target Hardware Address field in the ARP RARP frame is not equal to source MAC address Select 1 to indicate that THA field in the...

Page 150: ...tag priority from the pull down menu IP Parameters IP Protocol Filter Select Any ICMP UDP TCP or Other protocol from the pull down menu for IP Protocol filtering IP TTL Select 0 to indicate that the...

Page 151: ...o further specify an ICMP type value ICMP Type Value Specify an ICMP type value ICMP Code Filter This field is used to filter the ICMP code defined in the code field of the ICMP header Select any to f...

Page 152: ...stination port range The source port number is from 0 to 65535 TCP FIN Select 0 to indicate that the FIN value in TCP header is zero 1 to indicate the FIN value in TCP header is one Select any to indi...

Page 153: ...d send the TLV Select the option LLDP Configuration from the Switch Management menu and then the following screen page appears Port Tick the checkbox to enable LLDP Receiver Hold Time TTL Enter the am...

Page 154: ...c condition of error packets e g CRC fragment Jabber etc 4 Port Packet Analysis Statistics View each port s traffic condition of error packets e g RX TX frames of Multicast and Broadcast etc 5 LACP Mo...

Page 155: ...nts frame duplication arising from multiple paths existing in the active topology of Bridged LAN Learning A port in this state prepares to participate in frame relay Frame relay is temporarily disable...

Page 156: ...each port Frames Received Total frames received from each port Received Utilization The ratio of each port receiving traffic and current port s total bandwidth Bytes Sent The total bytes sent from cur...

Page 157: ...t or cleared Select Port Packet Error Statistics from the Switch Monitor menu and then the following screen page appears RX CRC Align Error CRC Align Error frames received RX Undersize Frames Undersiz...

Page 158: ...ollowing screen page appears Frames 64 Bytes 64 bytes frames received Frames 65 127 Bytes 65 127 bytes frames received Frames 128 255 Bytes 128 255 bytes frames received Frames 256 511 Bytes 256 511 b...

Page 159: ...view a list of all LACP ports information Select LACP Port Status from the LACP Monitor menu and then the following screen page appears Port Number The number of the port Partner ID The current opera...

Page 160: ...y in a manual or static LACP aggregation the selected ports share the same operational key Partner Port The corresponding port numbers that connect to the partner switch in LACP mode 4 5 5 2 LACP Stat...

Page 161: ...TP statistics 4 5 6 1 RSTP VLAN Bridge Overview RSTP VLAN Bridge Overview allows users to view a list of all RSTP VLANs brief information such as VLAN ID Bridge ID topology status and Root ID Select R...

Page 162: ...RSTP Port Status allows users to view a list of all RSTP ports information Select RSTP Port Status from the RSTP Monitor menu and then the following screen page appears In this page you can find the...

Page 163: ...ars RSTP Transmitted The total transmitted RSTP packets from current port STP Transmitted The total transmitted STP packets from current port TCN Transmitted The total transmitted TCN Topology Change...

Page 164: ...eal time 802 1X statistics 4 5 7 1 802 1X Port Status 802 1X Port Status allows users to view a list of all 802 1x ports information Select 802 1X Port Status from the 802 1x Monitor menu and then the...

Page 165: ...1X port statistics status of the Managed Switch select 802 1x Statistics from the 802 1x Monitor menu and then the following screen page shows up Select the port number from the pull down menu to view...

Page 166: ...VLAN The IGMP querier periodically sends IGMP general queries to all hosts and routers 224 0 0 1 on the local subnet to find out whether active multicast group members exist on the subnet Upon receiv...

Page 167: ...te to refresh the table VLAN ID VID of the specific VLAN Group The multicast IP address of IGMP querier Port The port s grouped in the specific multicast group 4 5 9 MAC Address Table When MAC Address...

Page 168: ...e TX Bias etc Select SFP Port Info from the SFP Information menu and then the following screen page appears Port The number of the port Speed View only field that shows the data rate of the slide in S...

Page 169: ...er dbm View only field that shows the slide in SFP module optical Transmission power RX Power dbm View only field that shows the slide in SFP module optical Receiver power 4 5 11 DCHP Snooping DHCP Sn...

Page 170: ...LLDP frames are received Chassis ID View only field that shows the MAC address of the LLDP frames received the MAC address of the neighboring device Remote Port View only field that shows the port num...

Page 171: ...earlier than the one mentioned above all events will lose when the system is shut down or rebooted 2 Update This allows users to update the latest firmware save current configuration or restore previ...

Page 172: ...clients Users may save or restore their configuration and update their Firmware on line Select Update from the System Utility menu and then the following screen page appears Protocol Select the prefer...

Page 173: ...ed a process completed message will pop up to remind users Click Stop to abort the current operation Select Update then press Enter to instruct the Managed Switch to update existing firmware configura...

Page 174: ...onnections Select Load Factory Setting Except Network Configuration from the System Utility menu the following screen page shows up Click OK to start loading factory settings except network configurat...

Page 175: ...hich will be saved by date 4 7 Save Configuration In order to save configuration setting permanently users need to save configuration first before resetting the Managed Switch Select Save Configuratio...

Page 176: ...de it needs to put this file dictionary cts under the directory raddb and modify these three files users clients conf and dictionary which are on the disc shipped with this product Please use any text...

Page 177: ...r auto upgrade of firmware and configuration please make sure the Managed Switch that you purchased can support DHCP Auto provisioning Setup procedures and auto provisioning process are described belo...

Page 178: ...eu 177 Step 2 Prepare dhcpd conf file You can find this file in Linux ISC DHCP server usr local etc dhcpd conf Step 3 Copy the marked text to dhcpd conf A sample of dhcp text is provided in Appendix...

Page 179: ...FTP Protocol 0 TFTP 3 Specify the FTP or TFTP IP address 4 Login FTP server anonymously 5 Specify FTP Server login name 6 Specify FTP Server login password 7 Specify the product model name 8 Specify...

Page 180: ...ce to be equal to DHCP when provisioning and it results in MD5 never match and causes the device to reboot endless In order for your Managed Switch to retrieve the correct configuration image in TFTP...

Page 181: ...will tell the device how to get a new firmware or configuration 2 The device will compare the firmware and configuration MD5 code form of DHCP option every time when it communicates with DHCP server...

Page 182: ...e Please copy the text below to your dhcpd conf file Please copy the text below to your dhcpd conf file option space CTS protocol 0 tftp 1 ftp option CTS protocol code 1 unsigned integer 8 option CTS...

Page 183: ...eu 182 vendor option space CTS option CTS firmware file name VRG 21412 WF_9 99 99 bin option CTS firmware md5 d8 e2 f0 de 7d a5 8e 2c 6e 4e a7 5a 39 78 07 d8 option CTS configuration file name metafil...

Page 184: ...10 06 0 97 Add a note in 2 6 9 Port command mode and 4 4 2 Port Configuration 1 02 00 2009 10 0 96 Additions in CLI ACL Hostname Txtcfg Remarking Management VLAN BPDU AdvFunc Additions in Web Manageme...

Reviews: