61 / 100
Siemens
Synco™ living Operating instructions
CE1B2707en
Building Technologies
Central apartment unit QAX910
23.08.2008
Select the event (or the events) that triggers a switching group configured for
Blind
:
Main menu > Switching groups > Switching group X > Events up cmd:
Main menu > Switching groups > Switching group X > Events down cmd:
Select the event (or the events) that triggers a switching group configured for
Scene
:
Main menu > Switching groups > Switching group X > Scene A or B
> Events scene:
The following events are available for triggering switching group functions:
Absence ON
Execution of command when changing from “Ab-
sence OFF” to "Absence ON” (= going).
Absence OFF
Execution of command when changing from "Ab-
sence ON” to "Absence OFF” (= coming).
Twilight switch
dark
Execution of command when the twilight switch
changes from BRIGHT to DARK.
Twilight switch
bright
Execution of command when the twilight switch
changes from DARK to BRIGHT.
Twilight switch
dark + absent
Execution of command when the twilight switch
changes from BRIGHT to DARK and when "Ab-
sence ON”, or when changing from "Absence OFF”
to "Absence ON” and twilight switch signals DARK.
Twilight switch
absent
Execution of command when the twilight switch
changes from DARK to BRIGHT and when "Ab-
sence ON”.
Smoke
Execution of command when the smoke detector
detects smoke.
Window / door
supervision
Execution of command when window / door super-
vision is triggered (see page 66).
Fault input X
(1 - 8)
Execution of command when an event is detected
at fault input X (1 - 8) (contact not in the normal
position).
Time switch for switching groups
Control of the individual switching groups takes place either manually or ac-
cording to the associated time switch. Available for each switching group are
7 weekdays and one special day, each with up to 8 switching points.
The time switch settings are made analogously to those of the room
time switch (refer to page 37).
Main menu > Switching groups > Switching group X > Time switch >