55 / 100
Siemens
Synco™ living Operating instructions
CE1B2707en
Building Technologies
Central apartment unit QAX910
23.08.2008
Forced DHW charging
With a long push on the central apartment unit’s
DHW
button,
one-time forced charging of the DHW storage tank to the Normal
setpoint is triggered. During the time forced charging is active, the
DHW symbol on the display flashes
.
Manual forced charging of the DHW storage tank can also be triggered via the
following operating line:
Main menu > DHW > Operating mode > Forced charging man:
State of DHW operating mode
The present state of the DHW operating mode can be displayed (Auto, Nor-
mal, Reduced, Protection).
Main menu > DHW > Operating mode > State:
Reason for DHW operating mode
If the current DHW operating mode does not satisfy your needs, the reason for
the operating mode can be displayed:
Main menu > DHW > Operating mode > Cause
Possible reasons for the current operating state:
•
Commissioning
•
Electrical heating
•
Forced charging
•
DHW charging lock
•
Legionella program
•
DHW operating mode (if not “Auto“)
•
Special day / holidays / absence
•
DHW time switch
•
Summer operation
DHW operating mode during absence
The DHW operating mode required during absence can be selected:
Main menu > DHW > Operating mode > Optg mode absence:
Factory setting
---
Your setting
--- (no impact, according to time program)
Normal
Reduced
Protection