65 / 100
Siemens
Synco™ living Operating instructions
CE1B2707en
Building Technologies
Central apartment unit QAX910
23.08.2008
The settings Release and Function become effective as soon as the central
apartment unit is set to "Absent" via
Absence
/
Supervision
button“:
3..30 Min
3..30 Min
On
Off
B2707Z04a
On
Of
f
On
On
On
Of
f
Of
f
Of
f
On
Off
t
On
Off
A
B
C
Simulation release (On, Off)
Light (On, Off) with function "Random"
Light (On, Off) with Function "Continuously on"
t
Time
The presence simulation is ended as soon as the central apartment unit is set
to "Present".
Supervision
Supervision delay
You can set a supervision delay to avoid generating a message upon supervi-
sion activation and simultaneously open window / door.
If supervised windows are open when supervision is activated, a constant
beep is sounded. The Info page Windows / Doors provides information on
which rooms contain open windows or doors.
Any open windows and doors can now be closed.
After you close the supervised window, the constant signal becomes a beep
that doubles in the last 15 seconds of supervision delay. The remaining su-
pervision delay time is also displayed on the central apartment unit.
You can set the desired delay time (00.00..59.55 ms) via the following com-
mand sequence:
Main menu > Supervision > Supervision delay:
The set delay time applies to all windows and doors.
Factory setting
05.00 ms
Your setting
You can set the volume of the signal / beep as desired (0..100%). While you
adjust the volume, a constant beep is sounded at the selected volume.
A
B
C