Technical data
4.5 Unit data
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
63
Table 4- 29 Technical data for 3-ph. 400 V AC, 1600 A to 3000 A, 4Q devices
Article number 6RA80 ..
..93-4DV62-...
..95-4DV62-...
..98-4DV62-...
Rated DC current
A
1600
2000
3000
Rated armature input current
2)
A
1328
1660
2490
Rated power
kW
672
840
1260
Power loss at
rated DC current (approx.)
W
5678
6781
10640
Rated field supply voltage
1)
V
2-ph. 480 V AC (+10% / -20%)
Rated field DC voltage
1)
V
390
390
390
Rated field DC current
A
40
40
40
Type of cooling
Forced ventilation
Forced ventilation
Forced ventilation
Rated fan supply voltage
V
3-ph. 400 V AC (±10%) 50 Hz / clockwise phase sequence
3-ph. 460 V AC (±10%) 60 Hz / clockwise phase sequence
Rated fan current
50 Hz
60 Hz
A
0.95
9)
1.25
9)
0.95
9)
1.25
9)
0.95
9)
1.25
9)
Fan air flow
m
3
/h
2400
2400
2400
Fan noise level
50 Hz
60 Hz
dB(A)
80.8
83.2
80.8
83.2
80.8
83.2
Dimensions (WxHxD)
mm
453x883x505
453x883x505
453x883x505
Weight (approx.)
kg
155
155
185