Descriptions of functions
10.3 Communication according to PROFIdrive
SINAMICS DCM DC Converter
Operating Instructions, 12/2018, A5E34763375A
419
10.3.2.3
Description of status words and actual values
Note
The reference parameter is also specified for the relevant process data. The process data is
generally normalized in accordance with parameters p2000 to r2004.
The following scalings apply:
•
A temperature of 100 °C corresponds to 100%
•
An electrical angle of 90° also corresponds to 100%.
Overview of status words and actual values
Table 10- 12 Overview of status words and actual values, see function diagram [2450]
Abbreviation
Name
Signal
number
Data type
1)
Interconnection
parameter
ZSW1
Status word 1
2
U16
r2089[0]
ZSW2
Status word 2
4
U16
r2089[1]
NACT_A
Speed setpoint A (16-bit)
6
I16
r0063
G1_ZSW
Encoder 1 status word
10
U16
r0481[0]
G1_XIST1
Encoder 1 actual position value 1
11
U32
r0482[0]
G1_XIST2
Encoder 1 actual position value 2
12
U32
r0483[0]
G2_ZSW
Encoder 2 status word
14
U16
r0481[1]
G2_XIST1
Encoder 2 actual position value 1
15
U32
r0482[1]
G2_XIST2
Encoder 2 actual position value 2
16
U32
r0483[1]
E_DIGITAL
Digital input (16-bit)
21
U16
r2089[2]
IAIST_GLATT
Absolute actual current value, smoothed
51
I16
r0027
MIST_GLATT
Actual torque value, smoothed
53
I16
r0080
PIST_GLATT
Active power, smoothed
54
I16
r0032
NACT_A_GLATT Actual speed value, smoothed
57
I16
r0021
MELD_NAMUR
VIK-NAMUR message bit bar
58
U16
r3113
FAULT_CODE
Fault code
301
U16
r2131
WARN_CODE
Alarm code
303
U16
r2132
ZSW1_BM
Status word 1, variant for BM
323
U16
r2089[0]
ZSW2_BM
Status word 2, variant for BM
325
U16
r2089[1]
CU_ZSW1
Status word 1 for Control Unit
501
U16
r2089[1]
1)
Data type according to PROFIdrive profile V4:
I16 = Integer16, I32 = Integer32, U16 = Unsigned16, U32 = Unsigned32