Descriptions of functions
10.28 Connecting units in parallel and in series
SINAMICS DCM DC Converter
608
Operating Instructions, 12/2018, A5E34763375A
Table 10- 71 6-pulse parallel connection n+m operation
Parameter
Master
Substitute master
Slave
p51799
Operating principle
0
The same as at the
master
The same as at the
master
p51800
Position in the topology
11 (Master)
13 (Substitute master)
12 (Slave)
p51801
Number of send data
Any
Any
Any
p51802
Minimum number of nodes n
The same as at the
master
The same as at the
master
p51812
Total number of nodes
n+m
The same as at the
master
The same as at the
master
p51803
n+m mode
1 (only armature)
2 (ar field)
The same as at the
master
0
p51804[..] Transmit data
Any
Any
Any
p51805
Bus terminator
0 or 1
1)
0 or 1
1)
0 or 1
1)
p51806
Station address
Unique address
Unique address
Unique address
p51807
Telegram failure time
0.1 s
0.1 s
0.1 s
p50082
Field operating mode
≠
0
0 (if only armature)
≠
0 (if ar field)
0 (no field)
p50076[..] Reduction in rated unit DC
current
-
The same as at the
master
The same as at the
master
p50078[..] Rated value for supply
voltage
-
The same as at the
master
The same as at the
master
p50100
Rated motor current
Rated motor
current/number of
SINAMICS DCM
The same as at the
master
The same as at the
master
p50110
Armature resistance Ra
2)
Actual armature
resistance × number of
SINAMICS DCM
The same as at the
master
The same as at the
master
p50111
Armature inductance La
2)
Actual armature
inductance × number of
SINAMICS DCM
The same as at the
master
The same as at the
master
p50114
Motor thermal time
constant
Motor thermal time
constant in s
The same as at the
master
The same as at the
master
p50140
Motor I
2
t monitoring,
response when starting
Application-specific
The same as at the
master
The same as at the
master
p50115 to
p50139
Field characteristic
-
The same as at the
master
(only if n+ m operation for
ar field)
The same as at the
master
p51591
La reduction factor
2)
-
The same as at the
master
The same as at the
master
p50357
Threshold for interrupted
tachometer
Application-specific
The same as at the
master
100% (tachometer
interruption monitoring
not active)
1)
= 1 at the two outermost units (= at the physical ends of the bus line)
= 0 on all of the other units
2)
The optimization run for current controller and precontrol (p50051 = 23 or 25) sets the correct values for these
parameters.