Technical data
4.5 Unit data
SINAMICS DCM DC Converter
54
Operating Instructions, 12/2018, A5E34763375A
Table 4- 18 Technical data for 3-ph. 575 V AC, 1600 A to 2800 A, 2Q devices
Article number 6RA80 ..
..93-4GS22-...
..95-4GS22-...
..96-4GS22-...
..97-4GS22-...
Rated DC current
A
1600
2000
2200
2800
Rated armature input current
2)
A
1328
1660
1826
2324
Rated power
kW
1104
1380
1518
1932
Power loss at
rated DC current (approx.)
W
6036
7073
7391
10530
Rated field DC current
A
40
40
40
40
Type of cooling
Forced
ventilation
Forced
ventilation
Forced
ventilation
Forced
ventilation
Rated fan supply voltage
V
3-ph. 400 V AC (±10%) 50 Hz / clockwise phase sequence
3-ph. 460 V AC (±10%) 60 Hz / clockwise phase sequence
Rated fan current
50 Hz
60 Hz
A
0.95
9)
1.25
0.95
9)
1.25
0.95
9)
1.25
0.95
9)
1.25
Fan air flow
m
3
/h
2400
2400
2400
2400
Fan noise level
50 Hz
60 Hz
dB(A)
80.3
83.2
80.3
83.2
80.3
83.2
80.3
83.2
Dimensions (WxHxD)
mm
453x883x505
453x883x505
453x883x505
453x883x505
Weight (approx.)
kg
135
135
165
165