Appendix
A.2 Parameter macros
Converter cabinet units
Operating Instructions, 07/2016, A5E03347396A
661
Sink
Source
Parameters
Description
DO
Parameters
Description
DO
p4056[0]
Type of analog inputs
TM31
2
Current 0...20 mA
TM31
p4056[1]
Type of analog inputs
TM31
2
Current 0...20 mA
TM31
p4076[0]
Type of analog outputs
TM31
0
Current 0...20 mA
TM31
p4076[1]
Type of analog outputs
TM31
0
Current 0...20 mA
TM31
p4071[0]
Signal analog output 0
TM31
r0063
Actual speed value smoothed
Vector
p4071[1]
Signal analog output 1
TM31
r0068
Absolute current actual value
Vector
p4100
Type of temperature sensor
TM31
0
Evaluation disabled
TM31
p4102[0]
Alarm threshold, temperature sens-
ing
TM31
251 °C
When this value is exceeded,
alarm A35211 is triggered.
TM31
p4102[1]
Fault threshold for temperature
sensing
TM31
251 °C
When this value is exceeded,
fault F35207 is triggered.
TM31
p7003
Winding system
Vector
1
Separate winding systems
Vector
Parameter macro p0700 = 5: PROFIdrive (70005)
This macro is used to set the PROFIdrive interface as the default command source.
Table A- 2
Parameter macro p0700 = 5: PROFIdrive
Sink
Source
Parameters
Description
DO
Parameters
Description
DO
p0840[0]
ON/OFF1
Vector
r2090.0
PZD 1 bit 0
Vector
p0844[0]
No OFF2_1
Vector
r2090.1
PZD 1 bit 1
Vector
p0845[0]
No OFF2_2
Vector
r0722.3
CU DI3
CU
p0848[0]
No OFF3_1
Vector
r2090.2
PZD 1 bit 2
Vector
p0849[0]
No OFF3_2
Vector
r0722.2
CU DI2
CU
p0806
Inhibit LOCAL mode
Vector
0
Vector
p0810
Changeover CDS bit 0
Vector
0
Vector
p0852
Enable operation
Vector
r2090.3
PZD 1 bit 3
Vector
p0854
Control request
Vector
r2090.10
PZD 1 bit 10
Vector
p0922
PROFIdrive PZD telegram selection Vector
999
Free telegram configuration
p1020
FSW bit 0
Vector
0
Vector
p1021
FSW bit 1
Vector
0
Vector
p1035
MOP raise
Vector
r2090.13
PZD 1 bit 13
Vector
p1036
MOP lower
Vector
r2090.14
PZD 1 bit 14
Vector
p1113
Setpoint inversion
Vector
r2090.11
PZD 1 bit 11
Vector
p1140
Enable RFG
Vector
r2090.4
PZD 1 bit 4
Vector
p1141
Continue RFG
Vector
r2090.5
PZD 1 bit 5
Vector
p1142
Enable nsetp
Vector
r2090.6
PZD 1 bit 6
Vector
p2103
Acknowledge fault 1
Vector
r2090.7
PZD 1 bit 7
Vector
p2104
Acknowledge fault 2
Vector
r4022.3
TM31 DI3
TM31
p2106
Ext. fault_1
Vector
r0722.1
CU DI1
CU