Analysis of BICO interconnections
The following parameters exist for the analysis of existing BICO interconnections:
•
r9481
Number of BICO interconnections
•
r9482[0...n]
BICO interconnections BI/CI parameters
•
r9483[0...n]
BICO interconnections BO/CO parameters
•
p9494
BICO interconnections, search signal source
•
p9495
BICO interconnections, search signal source number
•
p9496
BICO interconnections, search signal source first index
BICO interconnections to other drives
The following parameters are available for BICO interconnections to other drives:
•
r9490
Number of BICO interconnections to other drives
•
r9491[0...9]
BI/CI of BICO interconnections to other drives
•
r9492[0...9]
BO/CO of BICO interconnections to other drives
•
p9493[0...9]
Reset BICO interconnections to other drives
Binector-connector converters and connector-binector converters
Binector-connector converter
●
Several digital signals are converted to a 32-bit integer double word or to a 16-bit integer
word.
●
p2080[0...15] BI: PROFIdrive PZD send bit-serial