6',
W
W
W
6',
Figure 5-34 Feedback signal SDI when the motor is switched offLeft: SDI becomes inactive. Right: SDI
remains active
Switching off the motor when SDI is active (Page 283)
Parameter Description
p1051
Speed limit RFG positive direction of rotation (Factory setting depends on the Control
Unit)
p1052
Speed limit RFG negative direction of rotation (Factory setting depends on the Control
Unit)
p1135
OFF3 ramp-down time
p9501.00
1 signal: Enable extended functions.
0 signal: Disable extended functions.
p9501.17
1 signal: Enable SDI
0 signal: Inhibit SDI
p9509.08
1 signal: SDI becomes inactive when the motor is switched off
0 signal: SDI remains active when the motor is switched off
p9564
Tolerance (Factory setting: 12 degrees)
p9565
Delay time (Factory setting: 100 ms)
p9566
Stop response (Factory setting: 1)
0:
STOP A
1:
STOP B
r9714[0]
Load-side speed actual value [rpm]
Electrical speed of the motor. For induction motors, the mechanical speed is obtained
from the electrical speed and slip.
r9722.12
1 signal: SDI positive active
r9722.13
1 signal: SDI negative active
r9733
Effective setpoint speed limiting
[0]
Positive setpoint limitation
[1]
Negative setpoint limitation
[2]
Absolute setpoint speed limitation
Commissioning
5.12 Setting extended functions
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
196
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD