4.4.2.7
SIMATIC I/O modules
The diagrams only show the interconnection between the SIMATIC I/O modules and an
inverter shown as example. You can find additional information about the I/O modules in the
Internet
● S7-300 (
https://support.industry.siemens.com/cs/ww/en/view/19026151
)
https://support.industry.siemens.com/cs/ww/en/view/86140384
https://support.industry.siemens.com/cs/ww/en/view/12490437
)
https://support.industry.siemens.com/cs/ww/en/view/84133942
)
● ET 200pro (
https://support.industry.siemens.com/cs/ww/en/view/22098524
)
Components in the same control cabinet, PP-switching outputs
A control cabinet that has been designed and wired correctly does not contain any damaged
wiring or cross circuits.
As a consequence, for PP-switching fail-safe digital outputs, in an electrical cabinet you may
connect the inverter to the I/O module through a single channel cable connection. At the
inverter, you must connect both terminals of the fail-safe digital input with one another.
6DIHW\IXQFWLRQ
6DIHW\IXQFWLRQ
9'&
9'&
0
60
)',
)',
',
',
',
',
',&20
',&20
6
6,1$0,&6*
&8(
Figure 4-20 Connecting the PP switching module SM326 using a SINAMICS G120 with CU240E‑2 as
example
Installing
4.4 Controlling via a fail-safe digital input
Safety Integrated - SINAMICS G110M, G120, G120C, G120D and SIMATIC ET 200pro FC-2
76
Function Manual, 01/2017, FW V4.7 SP6, A5E34261271B AD