Protection against humidity
If a dry storage space is not available, protect the machine as follows against humidity:
● Wrap the machine in humidity-absorbent material.
● Wrap the machine in plastic film:
– Place a humidity meter inside the plastic film.
– Place desiccant within the plastic film.
– Pack the machine air-tight.
● Inspect the machine regularly.
NOTICE
Improper storage or transport
Damage to bearings can result from improper storage or transport.
● On machines that have been supplied with a rotor shipping brace, secure the rotor as per
the notes on transportation (Page 39).
● Protect the motor against strong radial shocks and vibration when storing, as the rotor
shipping brace cannot completely absorb these forces.
● If the customer has already mounted parts, such as a coupling or belt pulley, the bearings
can be damaged during transport. In this case, make sure that the customer uses a rotor
locking device.
WARNING
Risk of explosion due to damaged sealing materials
Storing the machine at temperatures that do not fall within the specified limits can damage the
material of the seals and cause them to fail. As a result, a potentially explosive gaseous
atmosphere can enter the machine and be ignited during commissioning. Explosions can
occur. This can result in death, serious injury or material damage.
The materials used are specially designed for the temperature range required by the
customer. Do not store the machine in conditions that lie outside the specified temperature
limits. The relevant temperature limits are specified on the rating plate.
Long-term storage
If you are storing a machine for more than six months, you must check its condition every six
months. Store the machine in accordance with the specifications in Section "Storage
(Page 41)", and if possible, packed.
● Check the motor for damage.
● Carry out any necessary maintenance work.
Preparations for use
4.18 Storage
SIMOTICS FD 1MM1
Operating Instructions 02/2019
43
Summary of Contents for SIMOTICS FD 1MM1 Series
Page 2: ...05 02 2019 16 03 V11 01 ...
Page 30: ...Description SIMOTICS FD 1MM1 30 Operating Instructions 02 2019 ...
Page 142: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1MM1 142 Operating Instructions 02 2019 ...
Page 166: ...Disposal 11 5 Disposal of components SIMOTICS FD 1MM1 166 Operating Instructions 02 2019 ...
Page 168: ...Service and Support SIMOTICS FD 1MM1 168 Operating Instructions 02 2019 ...
Page 172: ...Quality documents SIMOTICS FD 1MM1 172 Operating Instructions 02 2019 ...
Page 177: ......