7.9
Switching off
● If the controller does not do this automatically, switch on any anti-condensation heating
during stoppages. This will avoid the formation of condensation.
● Do not switch on the anti-condensation heating for at least two hours after the motor has
been switched off. This prevents damage to the winding insulation.
7.10
Setting the motor parameters at the converter
The selection of the motor type is used to pre-assign specific motor parameters and to optimize
the operating characteristics and behavior. If the incorrect motor type has been selected, then
this can result in undesirable operating states, for instance increased noise.
● If you use the SINAMICS G120/G150 or SINAMICS S120/S150 converter, you can set the
motor parameters using STARTER or the "Advanced Operating Panel" AOP30.
● If you use the SINAMICS G120P converter, you can set the motor parameters using the
"Intelligent Operator Panel" (IOP).
Note
Preset space-vector modulation for SINAMICS S converters
Unlike SINAMICS G converters, space-vector modulation is preset for SINAMICS S
converters. Provided permitted by the application, the space-vector modulation can be
changed manually to an optimized pulse pattern for SIMOTICS FD motors.
The SINAMICS parameter is p1802 = 19 in the STARTER and in the AOP30.
7.10.1
Selecting the motor type and motor data in the STARTER program
Prerequisites
● The motor is connected to the converter and is ready for operation.
● The converter must have at least software version 4.6.
● You have installed the STARTER software with at least version 4.3.1 with SSP, and you are
connected to the converter. You require SSP V4.6 for the SINAMICS G120P inverter.
● The STARTER program has been started. You are in the "Configuration" dialog screen form.
Selecting motor parameters
1. Enter a name for the motor in the "Motor name" input field.
Subsequent motor assignment is simplified by selecting a unique name.
2. Select the "Enter motor data" option.
Start-up
7.9 Switching off
SIMOTICS FD 1MM1
102
Operating Instructions 02/2019
Summary of Contents for SIMOTICS FD 1MM1 Series
Page 2: ...05 02 2019 16 03 V11 01 ...
Page 30: ...Description SIMOTICS FD 1MM1 30 Operating Instructions 02 2019 ...
Page 142: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1MM1 142 Operating Instructions 02 2019 ...
Page 166: ...Disposal 11 5 Disposal of components SIMOTICS FD 1MM1 166 Operating Instructions 02 2019 ...
Page 168: ...Service and Support SIMOTICS FD 1MM1 168 Operating Instructions 02 2019 ...
Page 172: ...Quality documents SIMOTICS FD 1MM1 172 Operating Instructions 02 2019 ...
Page 177: ......