This can result in death, serious injury or material damage.
● Avoid all of these processes in areas where there is risk of gas and dust explosions at non-
metallic exposed components, e.g. paint finishes. These discharge types are not addressed
in current standards.
● The non-metallic exposed components, e.g. paint finishes are subject to an electrostatic
suitability test in the factory. When supplied, the motor has its original paint finish.
Use the tested, original paint when repainting or touching up. It is possible to use a paint that
has not been tested by Siemens, which is however suitable from an electrostatic
perspective. The operating company is responsible for carrying out an electrostatic test of
the complete system.
2.7
Interference immunity
By selecting suitable signal cables and evaluation units, ensure that the interference immunity
of the machine is not diminished.
2.8
Interference voltages when operating the converter
Interference voltages when operating the converter
When a converter is in operation, the emitted interference varies in strength depending on the
converter (manufacturer, type, interference suppression measures undertaken). On machines
with integrated sensors (e.g. PTC thermistors), interference voltages caused by the converter
may occur on the sensor lead. This can cause faults which can result in eventual or immediate
death, serious injury or material damage.
● Comply with the EMC information provided by the manufacturer of the converter. This is how
you prevent the limit values stipulated by IEC/EN 61000-6-3 for the drive system (consisting
of the machine and converter) from being exceeded.
● You must put appropriate EMC measures in place.
2.9
Electromagnetic fields when operating electrical power engineering
installations
Electrical power equipment generate electromagnetic fields during operation. Potentially lethal
malfunctions can occur in medical implants, e.g. pacemakers, in the vicinity of electrical power
equipment. Data may be lost on magnetic or electronic data carriers.
● Protect the personnel working in the plant by taking appropriate measures, such as erecting
identifying markings, safety barriers and warning signs and giving safety talks.
● Observe the nationally applicable health and safety regulations.
● It is forbidden for people with pacemakers to be close to the machine.
● Do not carry any magnetic or electronic data media.
Safety information
2.7 Interference immunity
SIMOTICS FD 1MM1
20
Operating Instructions 02/2019
Summary of Contents for SIMOTICS FD 1MM1 Series
Page 2: ...05 02 2019 16 03 V11 01 ...
Page 30: ...Description SIMOTICS FD 1MM1 30 Operating Instructions 02 2019 ...
Page 142: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1MM1 142 Operating Instructions 02 2019 ...
Page 166: ...Disposal 11 5 Disposal of components SIMOTICS FD 1MM1 166 Operating Instructions 02 2019 ...
Page 168: ...Service and Support SIMOTICS FD 1MM1 168 Operating Instructions 02 2019 ...
Page 172: ...Quality documents SIMOTICS FD 1MM1 172 Operating Instructions 02 2019 ...
Page 177: ......