● Check that the maximum permissible clamping thickness of 10 mm for the cable lug or strap
is not exceeded.
● Fasten the clamping screw according to the following table. Screw-in depth and tightening
torque are different depending on whether cable lugs or ground terminals are used.
Screw
Screw-in depth
Tightening torque
When using cable lugs
M6
> 6 mm
8 Nm
M8
> 8 mm
20 Nm
M12 x 25
> 16 mm
38 Nm
M16 x 35
> 20 mm
92 Nm
When using grounding
terminals
M6
> 9 mm
8 Nm
M8
> 12 mm
20 Nm
M10
> 15 mm
40 Nm
M12
> 18 mm
70 Nm
M16
> 20 mm
170 Nm
See also
6.4.4
Connect metal shield in the terminal box
If you are using metal-armored cables that are inserted into the terminal or auxiliary terminal
boxes with non-intrinsically safe circuits, then ground the metal shield in the terminal box.
Additional grounding points are permissible.
● In terminal boxes with internal grounding part, connect the metal shield to the internal
grounding point.
● In terminal boxes without internal grounding part, connect the metal shield to one of the
green-yellow grounding terminals.
6.4.5
Connection without terminal box
If the machine was ordered without terminal box (where the cables are simply brought out of the
motor), then the proper connection must be made in an external terminal box.
WARNING
Incorrect dimensioning
Faults can occur if the appropriate technical data is not complied with when connecting up. For
instance, degree of protection, minimum air and creepage distances. These faults can result
in eventual or immediate death, serious injury or material damage.
● Ensure that the external terminal box is dimensioned according to the data on the rating
plate and is suitable for the respective use.
Electrical connection
6.4 Preparation
SIMOTICS FD 1MM1
80
Operating Instructions 02/2019
Summary of Contents for SIMOTICS FD 1MM1 Series
Page 2: ...05 02 2019 16 03 V11 01 ...
Page 30: ...Description SIMOTICS FD 1MM1 30 Operating Instructions 02 2019 ...
Page 142: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1MM1 142 Operating Instructions 02 2019 ...
Page 166: ...Disposal 11 5 Disposal of components SIMOTICS FD 1MM1 166 Operating Instructions 02 2019 ...
Page 168: ...Service and Support SIMOTICS FD 1MM1 168 Operating Instructions 02 2019 ...
Page 172: ...Quality documents SIMOTICS FD 1MM1 172 Operating Instructions 02 2019 ...
Page 177: ......