5. Enter the appropriate motor data in the "Motor data" table in the "Value" column.
– You can find the values for parameters p304...p311 on the motor rating plate.
– The value for parameter p335 (motor cooling method) is encrypted from the motor order
number:
Motor order number
Cooling method
Parameter p335
1LL1
IC01
0
1LP1
IC06
1
1LM1/1MM1
IC411
4
1LQ1/1MQ1
IC416
5
1LH1/1MH1
IC71W
6
1LN1/1MN1
IC86W
6
Figure 7-2
Entering the motor data
6. Click "Continue" to confirm your entries.