Install the V ring
1. Grease the axial sealing surface. The shaft seating remains ungreased.
①
V ring
②
Mounting aid washer
③
Protective ring
Figure 9-5
Install the V ring
2. Push the V ring
①
onto the shaft using an assembly disk
②
.
The V ring is in the correct axial position when the face surface is flush with the outer edge
of the V ring.
Install the protective ring for IP56 degree of protection
For degree of protection IP56, the V ring for the outer bearing seal is fitted with a sheet steel
protective ring
③
in the bearing cover.
1. Push the protective ring onto the shaft.
2. Verify that the ring is sufficiently pretensioned. Replace the protective ring, if necessary.
3. Position the protective ring so that one of the longitudinal grooves meets the corresponding
water separation groove at the bottom in the bearing cover flange or end shield.
9.2.4.6
Installing the V ring ("Increased degree of protection" option)
The grease chamber of the labyrinth sealing ring together with the V ring ensures compliance
with degree of protection IP65.
Maintenance
9.2 Corrective Maintenance
SIMOTICS FD 1MM1
138
Operating Instructions 02/2019
Summary of Contents for SIMOTICS FD 1MM1 Series
Page 2: ...05 02 2019 16 03 V11 01 ...
Page 30: ...Description SIMOTICS FD 1MM1 30 Operating Instructions 02 2019 ...
Page 142: ...Maintenance 9 2 Corrective Maintenance SIMOTICS FD 1MM1 142 Operating Instructions 02 2019 ...
Page 166: ...Disposal 11 5 Disposal of components SIMOTICS FD 1MM1 166 Operating Instructions 02 2019 ...
Page 168: ...Service and Support SIMOTICS FD 1MM1 168 Operating Instructions 02 2019 ...
Page 172: ...Quality documents SIMOTICS FD 1MM1 172 Operating Instructions 02 2019 ...
Page 177: ......