Service and maintenance
8.3 Checking and changing lubricants
BA 2030
Operating Instructions, 02/2021, A5E37880173A/RS-AM
85
Note
After the second flush, we recommend that an appropriate analysis institute checks the
quality of the flushed fluid.
Observe the symbols in the diagrams of the Mounting positions (Page 115):
Venting
Oil drain
Procedure
1.
After the oil has been drained, wipe the gearbox clean of any remaining mineral oil using a
cloth.
2.
Unscrew the vent plug.
3.
Fill the gearbox with a flushing oil, using a filter (filter mesh max. 25
μ
m). For the flushing
oil, use either the new oil or one that is compatible with the new oil and is less expensive.
4.
Operate the gearbox for 15 to 30 minutes under a low load.
5.
Place a suitable and sufficiently large receptacle underneath the oil drain plug.
6.
Remove the oil drain plug. Drain all the oil into the receptacle.
7.
After flushing, immediately seal the gearbox using the sealing element.
8.
Repeat this step for the second flushing.
You have now flushed the gearbox twice and can pour in the new oil.