Commissioning
5.5 Options of the VLplus heavy-duty bearing system
BA 2030
Operating Instructions, 02/2021, A5E37880173A/RS-AM
63
Setting the lubrication time
CAUTION
Setting the wrong lubrication time
The lubrication time is heavily influenced by the resistance in the lubricant channels and the
ambient temperature.
Check the actual lubrication time during operation.
The actual lubrication time is the time it takes for the lubricator to be completely emptied.
The lubrication time is influenced by the resistance in the lubricant channels and the ambient
temperature.
At an ambient temperature of -10° C, the actual lubrication time is twice that for the set
temperature.
At an ambient temperature of +40° C, the actual lubrication time drops to approximately half
that for the set temperature.
Figure 5-6
Lubrication time controller
Procedure
1.
Set the lubrication time with a 3 mm Allen key.
2.
Note the date of commissioning and the lubrication time on the lubricator.
The times in months listed in the table are guide values.
Table 5- 2
Timing in months on the lubrication time controller
Size
89
109
129
149
169
Months
12
12
12
12
11
Summary of Contents for SIMOGEAR BA 2030
Page 1: ......
Page 2: ......
Page 68: ...Operation BA 2030 66 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 72: ...Faults causes and remedies BA 2030 70 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 104: ...Disposal BA 2030 102 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 206: ...Your suggestions BA 2030 204 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 207: ......
Page 208: ......