Installation
4.3 Thread sizes and tightening torques for fastening bolts
BA 2030
Operating Instructions, 02/2021, A5E37880173A/RS-AM
31
On geared motors with a fan, leave sufficient free space for the entry of air. Observe the
installation conditions for the geared motor.
Provide sufficient lifting gear at the start of mounting and fitting work.
Observe the mounting position specified on the rating plate. This ensures that the correct
quantity of lubricant is provided.
Use all the fastening means that have been assigned to the particular mounting position and
mounting type.
Cap bolts cannot be used in some cases due to a lack of space. In such cases, please contact
Technical Support quoting the type of gearbox.
4.3
Thread sizes and tightening torques for fastening bolts
The general tolerance for the tightening torque is 10%. The tightening torque is based on a
friction coefficient of
μ
= 0.14.
Table 4- 1
Tightening torques for fixing screws
Thread size
Tightening torque for property class
8.8
10.9
12.9
Nm
Nm
Nm
M4
3
4
5
M5
6
9
10
M6
10
15
18
M8
25
35
41
M10
50
70
85
M12
90
120
145
M16
210
295
355
M20
450
580
690
M24
750
1 000
1 200
M30
1 500
2 000
2 400
M36
2 500
3 600
4 200
Summary of Contents for SIMOGEAR BA 2030
Page 1: ......
Page 2: ......
Page 68: ...Operation BA 2030 66 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 72: ...Faults causes and remedies BA 2030 70 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 104: ...Disposal BA 2030 102 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 206: ...Your suggestions BA 2030 204 Operating Instructions 02 2021 A5E37880173A RS AM ...
Page 207: ......
Page 208: ......