07.97
1 NC/Drive Machine Data
1.11.3 611D drive machine data FDD/MSD (as from SW 4)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
1798 Firmware date
0
32 767
–
–
1799 Firmware version
0
32 767
–
–
2005 No. of encoder marks motor
measuring system
2 048
8 192
–
Incr/rev
2102 Motor code number
0
65 535
–
–
2103 Rated motor current
0.0
500.0
–
A
2117 Motor moment of inertia
0.0
32.0
–
kgm
2
2120 P gain current controller
10.0
10 000.0
–
V/A
2121 Reset time current controller
2 000.0
8 000.0
–
µ
s
2130 Rated motor power
0.0
1 500.0
–
kW
2132 Rated motor voltage
0.0
5 000.0
–
V
2134 Rated motor frequency
0.0
3 000.0
–
Hz
2135 Motor no-load voltage
0.0
500.0
–
V
2136 Motor no-load current
0.0
500.0
–
A
2137 Stator resistance cold
0.0
20.0
–
2138 Rotor resistance cold
0.0
20.0
–
2139 Stator leakage reactance
0.0
100.0
–
2140 Rotor leakage reactance
0.0
100.0
–
2141 Magnetizing reactance
0.0
1 000.0
–
2142 Speed at start of field
weakening
0.0
50 000.0
–
rev/min
2143 Upper speed L
h
characteristic
0.0
50 000.0
–
rev/min
2144 Gain factor L
h
characteristic
100.0
500.0
–
%
2145 Breakdown torque reduction
factor
100.0
1 000.0
–
%
2146 Maximum motor speed
0.0
50 000.0
–
rev/min
2147 Speed limitation
7 000.0/
8 000.0
50 000.0
–
rev/min
2150 P gain flux controller
400.0
100 000.0
–
A/Vs
2151 Reset time flux controller
10.0
500.0
–
ms
2230 1st torque limiting value
100.0
900.0
–
%
2231 2nd torque limiting value
100.0
100.0
–
%
2232 Switching speed from MD 2230
to MD 2231
6 000.0
50 000.0
–
rev/min
2233 Generative limitation
100.0
100.0
–
%
2234 Hysteresis MD 1232
50.0
1 000.0
–
rev/min
2235 1st power limit value
100.0
900.0
–
%
2236 2nd power limit value
100.0
100.0
–
%
2238 Current limit
150.0
300.0
–
%
2239 Torque limit setup operation
1.0
100.0
–
%
2245 Threshold speed-dependent
torque setpoint smoothing
0.0
50 000.0
–
rev/min
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
1–75
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D
Page 2: ......