1 NC/Drive Machine Data
09.95
1.11.3 611D drive machine data FDD/MSD (as from SW 4)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
1515 Bandwidth speed setp. filter 1
500.0
7 999.0
–
Hz
1516 Bandwidth counter speed
setpoint filter 1
0.0
7 999.0
–
Hz
1517 Stop frequency speed setpoint
filter 2
3 500.0
7 999.0
–
Hz
1518 Bandwidth
speed
setp.
filter
2
500.0
7 999.0
–
Hz
1519 Bandwidth counter speed
setpoint filter 2
0.0
7 999.0
–
Hz
1520 Band stop nat. freq. speed
setp. frequency 1 (from SW 5)
100
141
--
%
1521 Band stop nat. freq. speed
setp. frequency 2 (from SW 5)
100
141
--
%
1600 Concealab. alarms (Power On)
0000
FFFF
–
Hex
1601 Concealable alarms (Reset)
0000
FFFF
–
Hex
1602 Motor temperature warning
threshold
120
200
–
°C
1603 Timer motor temperature alarm
240
600
–
s
1604 DC link undervoltage warning
threshold
200
600
–
V
1605 Timer controller against stop
200.0
10 000.0
–
ms
1606 Threshold controller against
stop
8 000.0/
30.0
50 000.0
–
rev/min
1607 Motor temperature cut-off limit
155
200
–
°C
1608 Fixed temperature
0
200
–
°C
1610 Diagnosis functions
0000/
0001
0001
–
Hex
1611 Response threshold dn/dt
800
1 600
–
%
1612 Configured shutdown reaction
PO alarms
0D3C/
FFFF
FFFF
–
Hex
1613 Configured shutdown reaction
reset alarms
0100/
FFFF
FFFF
–
Hex
1615 Tolerance concentricity monit.
20
100.0
–
rev/min
1620 Bits variable message function
0000
FFFF
–
Hex
1621 Signal number variable
message function
0
100
–
–
1622 Add. variable message function
0000
FFFF
–
Hex
1–72
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
SINUMERIK 840C (IA)