10.94
1 NC/Drive Machine Data
1.11.1 611A drive machine data MSD (SW 3)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
254
Display of active functions
1
--
--
--
HEX
255
Display of active functions
2
--
--
--
HEX
258
Speed for max. motor
operational speed Motor2
Motor
max.
speed
Motor
max.
speed
--
rev/min
260
n
min
for n
act
< n
min
message
Motor 2
12
Rated speed
--
rev/min
261
Creep speed pulse
suppression
Motor 2
Rated
speed
256
Rated speed
--
rev/min
262
n
x
for n
act
< n
x
message
Motor 2
6000
Motor max.
speed
--
rev/min
263
Tolerance band for
n
set
= n
act
message Motor 2
20
Rat. speed -1
16
--
rev/min
264
Speed limitation
Motor 2
Max.
speed
Motor max.
speed
--
rev/min
265
P-gain speed controller
Motor 2
32.0
120.0
--
--
266
Reset time speed controller
Motor 2
20
6000
--
ms
267
Switchover speed motor
encoder evalution Motor 2
32000
32000
--
rev/min
268
Hysteresis MD 267
Motor 2
50
500
--
rev/min
269
1st torque limiting value
Motor 2
100
180
--
%
270
Generative limitation
Motor 2
100
100
--
%
271
2nd torque limiting value
Motor 2
50
100
--
%
272
Switchover speed for MD 270
Motor 2
500
Motor max.
speed
--
rev/min
273
Hysteresis MD 272
Motor 2
20
Motor max.
speed
--
rev/min
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
1–59
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D