1 NC/Drive Machine Data
10.94
1.11.1 611A drive machine data MSD (SW 3)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
175
Gain factor x
n
- characteristic
Motor 1
Depends
on motor
300
--
%
176
Breakdown torque
reduction factor Motor 1
100
150
--
%
179
Selection min/max memory
0
2
--
HEX
180
Enable motor switchover
0
1
--
HEX
181
Address for min/max memory
0D02
FFFF
--
HEX
182
Minimum value min/max
memory
--
--
--
HEX
183
Maximum value min/max
memory
--
--
--
HEX
185
Address for monitoring 1
0C06
FFFF
--
HEX
186
Threshold for monitoring 1
0000
FFFF
--
HEX
187
ON-delay
Monitoring 1
0
10.00
--
s
188
Drop delay
Monitoring 1
0
10.00
--
s
189
Hysteresis monitoring 1
1
FFFF
--
HEX
190
Address for monitoring 2
0C06
FFFF
--
HEX
191
Threshold for monitoring 2
0000
FFFF
--
HEX
192
ON-delay
Monitoring 2
0
10.00
--
s
193
Drop delay
Monitoring 2
0
10.00
--
s
194
Hysteresis monitoring 2
1
0FFFF
--
HEX
195
Lower adaptation speed
Motor 1
1000
(Max. speed)
-2
--
rev/min
196
Upper adaptation speed
Motor 1
1200
(Max. speed)
--
rev/min
--
198
P gain upper adaptation
speed
Motor1
24.0
120.0
--
--
199
Reduction factor P-gain
Motor 1
100
200
--
%
1–56
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D