09.95
1 NC/Drive Machine Data
1.11.3 611D drive machine data FDD/MSD (as from SW 4)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
1103 Motor rated current
0.0
500.0
–
A
1104 Maximum motor current
0.0
500.0
–
A
1105 Reduction of maximum motor
current
100
100
–
%
1106 Power section code number
0000
FFFF
–
Hex
1107 Transistor limit current power
section
200.0
500.0
–
A
1108 Thermal limit current power
section
200.0
500.0
–
A
1109 Limit current power section S6
200.0
500.0
–
A
1111 Rated current power section
200.0
500.0
–
A
1112 Number of pole pairs motor
0
6
–
–
1113 Torque constant
0.0
5.0
–
Nm/A
1114 Voltage constant
0.0
300.0
–
V
1115 Armature resistance
0.0
20.0
–
1116 Armature inductance
0.0
100.0
–
mH
1117 Motor moment of inertia
0.0
32.0
–
kgm
2
1118 Motor zero-speed current
0.0
500.0
–
A
1119 Inductance of series reactor
10.0
65.0
--
mH
1120 P gain current controller
2 000.0
10 000.0
–
V/A
1121 Reset time current controller
0.0
8 000.0
–
µ
s
1124 Symmetrizing reference model
current control loop
0.5
1.0
–
–
1125 Ramp-up time 1 in V/Hz
operation (from SW 5)
5.0
100.0
--
s
1126 Ramp-up time 2 in V/Hz
operation (from SW 5)
5.0
100.0
--
s
1127 Voltage if Hz = 0 V/Hz
operation (from SW 5)
2.0
10.0
–
V
1129 cos
power factor
(from SW 5)
0.8
1.0
--
--
1130 Motor rated power
0.0
1 500.0
–
kW
1132 Motor rated voltage
0.0
5 000.0
–
V
1134 Motor rated frequency
0.0
3 000.0
–
Hz
1135 Motor no-load voltage
0.0
500.0
–
V
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60