1 NC/Drive Machine Data
08.96
1.11.3 611D drive machine data FDD/MSD (as from SW 4)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
1246 Hysteresis for speed-depen-
dent torque setpoint smoothing
50.0
1 000.0
–
rev/min
1250 Corner frequency current
actual value smoothing
100.0
8 000.0
–
Hz
1252 Corner frequency torque
setpoint smoothing
100.0
8 000.0
–
Hz
1254 Time constant current
monitoring
0.05
2.0
ms
1400 Motor rated speed
1 450.0
25 000.0
–
rev/min
1401 Speed for maximum motor
operational speed
1 500.0
50 000.0
–
rev/min
1403 Creep speed pulse
suppression
0.0/2.0
7 200.0
–
rev/min
1404 Timer for pulse suppression
100.0/
5 000.0
100 000.0
–
ms
1405 Monitoring speed motor
110.0/
100.0
110.0
–
%
1406 Speed controller type
1
1
–
–
1407 P gain speed controller
0.3
100 000.0
–
Nm/s
-1
1408 P gain upper adaptation speed
0.3
100 000.0
–
Nm/s
-1
1409 Reset time speed controller
100.0
500.0
–
ms
1410 Reset time upper adaptation
speed
10.0
500.0
–
ms
1411 Lower adaptation speed
0.0
50 000.0
–
rev/min
1412 Upper adaptation speed
0.0
50 000.0
–
rev/min
1413 Select adaptation speed
controller
0
1
–
–
1414 Natural frequency ref. model
speed
0.0
8 000.0
–
Hz
1415 Damping ref. model speed
1.0
5.0
–
–
1416 Symmetrizing ref. model speed
0.0
1.0
–
–
1417 n
x
for n
act
< n
x
message
6 000.0
50 000.0
–
rev/min
1418 n
min
for n
act
< n
min
message
5.0
25 000.0
–
rev/min
1420 Maximum motor speed setup
mode
30.0
50 000.0
–
rev/min
1421 Time constant integrator
feedback
0.0
1 000.0
–
ms
1–70
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D