01.99
1 NC/Drive Machine Data
1.9.2 Axis-specific MD2
D e s i g n a t i o n
MD
No.
Standard
value
Maximum
input value
Reference
system
Input
unit
1708*
Time const. paral. model 2nd para. set
6 000
16 000
--
0.01 ms
1712*
Time const. paral. model 3rd para. set
6 000
16 000
--
0.01 ms
1716*
Time const. paral. model 4th para. set
6 000
16 000
--
0.01 ms
1720*
Time const. paral. model 5th para. set
6 000
16 000
--
0.01 ms
1724*
Time const. paral. model 6th para. set
6 000
16 000
--
0.01 ms
1728*
Time const. paral. model 7th para. set
6 000
16 000
--
0.01 ms
1732*
Time const. paral. model 8th para. set
6 000
16 000
--
0.01 ms
1736*
Alarm limit velocity
1st para. set
1)
11 000
9999 9999
IS
1000 units/min
1740*
Alarm limit velocity
2nd para. set
1)
11 000
9999 9999
IS
1000 units/min
1744*
Alarm limit velocity
3rd para. set
1)
11 000
9999 9999
IS
1000 units/min
1748*
Alarm limit velocity
4th para. set
1)
11 000
9999 9999
IS
1000 units/min
1752*
Alarm limit velocity
5th para. set
1)
11 000
9999 9999
IS
1000 units/min
1756*
Alarm limit velocity
6th para. set
1)
11 000
9999 9999
IS
1000 units/min
1760*
Alarm limit velocity
7th para. set
1)
11 000
9999 9999
IS
1000 units/min
1764*
Alarm limit velocity
8th para. set
1)
11 000
9999 9999
IS
1000 units/min
1768*
Alarm limit acceleration
1st para. set
1)
55
16 000
IS
units/s
2
1772*
Alarm limit acceleration
2nd para. set
1)
55
16 000
IS
units/s
2
1776*
Alarm limit acceleration
3rd para. set
1)
55
16 000
IS
units/s
2
1780*
Alarm limit acceleration
4th para. set
1)
55
16 000
IS
units/s
2
1784*
Alarm limit acceleration
5th para. set
1)
55
16 000
IS
units/s
2
1788*
Alarm limit acceleration
6th para. set
1)
55
16 000
IS
units/s
2
1792*
Alarm limit acceleration
7th para. set
1)
55
16 000
IS
units/s
2
1796*
Alarm limit acceleration
8th para. set
1)
55
16 000
IS
units/s
2
_______
1)
SW 4 and higher
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
1–41
SINUMERIK 840C (IA)
Summary of Contents for SIMODRIVE 611-D
Page 2: ......