1 NC/Drive Machine Data
08.96
1.11.3 611D drive machine data FDD/MSD (as from SW 4)
D e s i g n a t i o n
MD
No.
Standard
value
Maximum input
value
Reference
system
Input
unit
1136 Motor no-load current
0.0
500.0
–
A
1137 Stator resistance cold
0.0
20.0
–
1138 Rotor resistance cold
0.0
20.0
–
1139 Stator leakage reactance
0.0
100.0
–
1140 Rotor leakage reactance
0.0
100.0
–
1141 Magnetizing reactance
0.0
1 000.0
–
1142 Speed at start of field
weakening
0.0
50 000.0
–
rev/min
1143 Upper speed L
h
characteristic
0.0
50 000.0
–
rev/min
1144 Gain factor L
h
characterisitc
100.0
500.0
–
%
1145 Breakdown torque reduction
factor
100.0
1 000.0
–
%
1146 Maximum motor speed
1500.0
50 000.0
–
rev/min
1147 Speed limitiation
7 000.0/
8 000.0
50 000.0
–
rev/min
1150 P gain flux controller
400.0
100 000.0
–
A/Vs
1151 Reset time flux controller
10.0
500.0
–
ms
1160 Oper. speed flux acquisition
(from SW 5)
1 500.0
50 000.0
--
rev/min
1161 DC link fixed voltage
600
700
–
V
1190 Torque limit value
100.0
10 000.0
–
Nm
1191 Adaptation factor servo limit
torque
1.0
100.0
–
–
1200 No. of current setpoint filters
1
4
–
–
1201 Type of current setpoint filter
Low pass
Band stop
–
–
1202 Natural frequency current
setpoint filter 1
2 000.0
8 000.0
–
Hz
1203 Damping current setp. filter 1
0.7
5.0
–
–
1204 Natural frequency current
setpoint filter 2
0.0
8 000.0
–
Hz
1205 Damping current setp. filter 2
1.0
5.0
–
–
1206 Natural frequency current
setpoint filter 3
0.0
8 000.0
–
Hz
1207 Damping current setp. filter 3
1.0
5.0
–
–
1208 Natural frequency current
setpoint filter 4
0.0
8 000.0
–
Hz
1209 Damping current setp. filter 4
1.0
5.0
–
–
1–68
© Siemens AG 1992 All Rights Reserved 6FC5197- AA60
SINUMERIK 840C (IA)